![Siemens SITRANS FC430 Скачать руководство пользователя страница 459](http://html.mh-extra.com/html/siemens/sitrans-fc430/sitrans-fc430_operating-instructions-manual_374486459.webp)
HMI menu ID Parameter
Description
Default value
[unit]
value range
Access
level
2.8.4.1
Damping value
Define the damping filter time
constant.
1.0 s
0.0 to 100 s
2.8.4.2
values (1)
Select the values which shall be
filtered for the local display.
● Mass flow
● Volume flow
● Standard
volume flow
● Density
● Medium
temperature
● Standard
Volume flow
● Fraction A
● Fraction B
● Fraction A %
● Fraction B %
● Dosing
Table E-24
View 1
HMI menu ID Parameter
Description
Default value
[unit]
value range
Access
level
2.8.5.1
View
Select the view type.
Three values
● Single value
● Three values
● One value and
bargraph
● One value and
graph
● Six values
● Six diagnostic
values
User
2.8.5.2
1st value
Select the first value for the view. Mass flow
● Mass flow
● Volume flow
● Standard
volume flow
● Density
● Medium
temperature
● Fraction A
● Fraction B
● Fraction A %
● Fraction B %
User
Default settings
E.8 Local display
FC430 (From firmware 4.0)
Operating Instructions, 06/2017, A5E39789392-AA
459
Содержание SITRANS FC430
Страница 40: ...Description 3 5 Theory of operation FC430 From firmware 4 0 40 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 94: ...Connecting 5 4 Device nameplates FC430 From firmware 4 0 94 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 150: ...Operating FC430 7 2 HMI FC430 From firmware 4 0 150 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 182: ...Functions 8 16 Maintenance FC430 From firmware 4 0 182 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 262: ...Dimensions and weight 12 5 Mounting bracket FC430 From firmware 4 0 262 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 534: ...Index FC430 From firmware 4 0 534 Operating Instructions 06 2017 A5E39789392 AA ...