HMI menu ID Parameter
Description
Default value
[unit]
Value range
Access
level
2.1.3.4
Standard Deviation Lim‐
it
Set limit for zero-point adjust‐
ment "Standard Deviation" val‐
ue.
1)
0 to 3682800.0
User
2.1.3.5
Standard Deviation
Standard deviation during auto
zero-point adjustment.
[kg/h]
Read
only
2.1.3.6
Offset Limit
Set limit for "Zero Offset".
[kg/h]
User
2.1.3.7
Offset
Zero-point offset compensates
for sensor variation due to proc‐
ess conditions.
[kg/h]
Read
only
2.1.3.8
Offset
Enter agreed zero-point offset
value.
[kg/h]
User
2.1.4
Aerated flow
2.1.4.1
Aerated Flow Filter
Set the process value filter for
aerated flow. Auto means that
filtering starts automatically
when measuring aerated flow.
Auto
(non-SIL var‐
iants)
Off
(SIL variants)
● Off
● On
● Auto
User
2.1.4.2
Filter Time Constant
10 s
● 0.5 s
● 1 s
● 2 s
● 5 s
● 10 s
● 20 s
● 30 s User
defined
User
2.1.4.3
Alarm Limit
Set alarm limit in percent of ac‐
cepted bad measurements.
0
[%]
0 to 99
Expert
2.1.4.4
Warning Limit
Set warning limit in percent of
accepted bad measurements.
0
[%]
0 to 99
Expert
2.1.4.5
Measurement Sample
Time
Set the time period over which
the actual percentage of unsta‐
ble measurements is calculated
5
[s]
1 to 10
Expert
2.1.4.6
Filter Start Hysteresis
Set the hysteresis value. The fil‐
ter is active when the hysteresis
value is exceeded.
0.015
[V]
0 to 0.124
Expert
2.1.4.7
Minimum Filtering Time Set the filtering time. The filter‐
ing time is reset each time hys‐
teresis band is exceeded.
100
[cycles]
0 to 65535
Expert
2.1.4.8
Filter Iteration
Set the number of times to re‐
peat the same filter. Increasing
the number will increase the
damping.
3
1 to 5
Expert
Default settings
E.1 Sensor
FC430 (From firmware 4.0)
326
Operating Instructions, 06/2017, A5E39789392-AA
Содержание SITRANS FC430
Страница 40: ...Description 3 5 Theory of operation FC430 From firmware 4 0 40 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 94: ...Connecting 5 4 Device nameplates FC430 From firmware 4 0 94 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 150: ...Operating FC430 7 2 HMI FC430 From firmware 4 0 150 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 182: ...Functions 8 16 Maintenance FC430 From firmware 4 0 182 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 262: ...Dimensions and weight 12 5 Mounting bracket FC430 From firmware 4 0 262 Operating Instructions 06 2017 A5E39789392 AA ...
Страница 534: ...Index FC430 From firmware 4 0 534 Operating Instructions 06 2017 A5E39789392 AA ...