Maintenance and diagnostics
4.7 SensorFlash
FST030
284
Function Manual, 04/2017, A5E35693328-AA
4.7.5.2
Data logging mode
Description
Select between a momentary value or an averaged value calculated over one logging
interval.
Setting Log instantaneous, Log average value
Default Log instantaneous
Related
Path
Mai
ntenance and diagnostics → SensorFlash → Data logging → Data logging mode
4.7.5.3
Logging interval
Description
Defines the interval for logging. Granularity is 10 ms.
Setting 10 ms; 20 ms; 100 ms; 200 ms; 500 ms; 1 s; 5 s; 10 s; 15 s; 30 s; 1 min; 5 min; 15 min; 30
min; 1 h; 2 h; 4 h; 6 h; 12 h; 24 h
Default 5 s
Related
Path
Maintenance and diagnostics → SensorFlash → Data logging → Logging interval
4.7.5.4
Process values
Logging value 1...20
Description
The process value to be logged can be selected in this parameter.
Logged process values are an indicator that you have to stop logging before you can change
the logged process values.
Setting Disabled; Volume flow; Mass flow; Standard volume flow; Sound velocity; Flow velocity;
LiquIdent; Density; Medium temperature; Pressure; Kinematic viscosity; Sensor tempera-
ture (RTD); Auxiliary temperature (RTD); Totalizer 1; Totalizer 2; Totalizer 3
Default Disabled
Related
This parameter is only available if Data logging is enabled.
Path
Maintenance and diagnostics
→ SensorFlash → Data logging → Process values → Logging
value 1...20
Содержание SITRANS F
Страница 1: ...Function Manual Answers for industry 04 2017 Edition Ultrasonic Flowmeters FST030 SITRANS F ...
Страница 2: ......
Страница 18: ...Table of contents FST030 16 Function Manual 04 2017 A5E35693328 AA ...
Страница 22: ...Introduction 1 7 Device documentation package FST030 20 Function Manual 04 2017 A5E35693328 AA ...
Страница 24: ...Quick Start 2 5 Copy configuration FST030 22 Function Manual 04 2017 A5E35693328 AA ...
Страница 310: ...Maintenance and diagnostics 4 12 Firmware update FST030 308 Function Manual 04 2017 A5E35693328 AA ...
Страница 332: ...Communication 5 3 Modbus Channel 1 FST030 330 Function Manual 04 2017 A5E35693328 AA ...
Страница 336: ...Security 6 8 Logout FST030 334 Function Manual 04 2017 A5E35693328 AA ...
Страница 338: ...Language 7 1 Language FST030 336 Function Manual 04 2017 A5E35693328 AA ...
Страница 340: ...Support A 1 Technical support FST030 338 Function Manual 04 2017 A5E35693328 AA ...
Страница 346: ...Glossary FST030 344 Function Manual 04 2017 A5E35693328 AA ...
Страница 348: ...Index FST030 346 Function Manual 04 2017 A5E35693328 AA ...
Страница 349: ......