MAG 8000 & MAG 8000 CT
5
SFIDK.PS.026.D9.02
2.
Installation
2.1 Mechanical installation
Installation conditions for MAG 8000 CT is
different from MAG 8000, for detailed infor-
mation please see OIML R49 and MI-001
certificates for MAG 8000 CT
.
Please note sensor flow direction.
Flow direction „forward“ is mandatory for MAG
8000 CT.
2. Installation
Flow direction
Inlet and outlet condition
Horizontal pipes
Vertical pipes (MAG 8000)
To achieve most accurate flow measurement it
is essential to have minimum straight lengths of
the inlet and outlet pipes as shown.
(D
i
: sensor diameter).
Installation in horizontal pipes is mandatory for
MAG 8000 CT.
The sensor must be mounted as shown in the
upper figure. Do not mount the sensor as shown
in the lower figure. This will position the
electrodes at the top where there is possibility
for air bubbles and at the bottom where there is
possibility for mud, sludge, sand etc.
If using
“Empty Pipe Detection”
, the sensor
should be tilted 45° as shown in the upper
figure to maximize full pipe detection and
provide accurate volume calculations.
Note
Physical installation of the battery pack may
influence the battery capacity. Optimal battery
capacity is achieved with the battery pack in
an upright position. The marked installation
examples with the dotted cross will affect the
battery capacity.
Recommended installation is in a vertical/inclin-
ed pipe to minimize the wear and deposits in
the sensor.
If the process flow direction is opposite of the
sensor’s flow direction label, forward flow rates
can be restored via software parameter FT327,
customer adjusting factor to “-1“.
Содержание SITRANS F M MAG 8000
Страница 60: ...MAG 8000 MAG 8000 CT 60 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Страница 61: ...MAG 8000 MAG 8000 CT 61 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Страница 62: ...MAG 8000 MAG 8000 CT 62 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Страница 63: ...MAG 8000 MAG 8000 CT 63 SFIDK PS 026 D9 02 10 Approvals and certificates ...