MAG 8000 & MAG 8000 CT
37
SFIDK.PS.026.D9.02
5. Operation
5.4.3 Installation and
replacement of
batteries
Position 1-2
Remove the top of the transmitter.
Position 3-4
(only replacement)
Dispose of the silicagel bag. Check the O-ring for damage or deformity. To ensure the continued
IP68 enclosure rating replace the O-ring and smear the O-ring with an acid free lubricating gel.
Position 5-8
Remove the battery pack by pushing the locking tab and loosen the strip. Take the battery pack
out with power connected, place and secure the new battery pack.
Place the new silicagel pack on top of the battery pack, after removing the plastic bag. The silicagel
prevents condensation within the meter.
Position 9-10
Connect the battery pack. After each power up the meter asks if a new battery has been installed
and the internal battery calculation has to be reset. As this information will come soon after the
power has been connected the wire nail or display key must be activated to reset the battery. The
battery
Reset
will reset the operating time calculate and ensure the correct indication of the
remaining battery capacity. After resetting the battery capacity can date and time be adjusted -
see section 5.2 “Operator menu“ index 4 for more information.
Position 11
Replace the top lid and if necessary, adjust the time and the date via the Flow Tool.
NOTE
All sealed MAG 8000 CT meters have to be verified again when sealings with mark „
A
“ (see
drawing) is broken.
Battery disposal
Disposal of used batteries is regulated under The European Community (EC) two directives, 91/
157/EEC and 93/86/EEC. These directives are implemented by each member country of the EC
independently and in a different way - please contact Siemens for specific regional rules for
disposal of batteries.
For batteries bought from Siemens, a disposal service is offered upon customer request. A
Technical Notice with further recommendations is available upon request.
Package containing used batteries shall bear the inscription:
“USED LITHIUM CELLS“
.
MAG 8000 CT
Содержание SITRANS F M MAG 8000
Страница 60: ...MAG 8000 MAG 8000 CT 60 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Страница 61: ...MAG 8000 MAG 8000 CT 61 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Страница 62: ...MAG 8000 MAG 8000 CT 62 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Страница 63: ...MAG 8000 MAG 8000 CT 63 SFIDK PS 026 D9 02 10 Approvals and certificates ...