4. Commissioning
Data protection by
password
Device driver
The Device Drivers are related to the meter version and is automatic selected in “Automatic”
mode. In “Manual” mode, the meter version is manually selected and the version check is
automatically made when data is uploaded or downloaded.
New device drivers are included in the latest Flow Tool program available at www.siemens.com/
flow under Battery operated Flowmeter - Tools & Downloads - SITRANS F M MAG 8000.
The meter information is software protected by a password. The default factory password is
“1000” and can be changed after gaining access to the meter. If the password is lost, it can
be reset with a new password using the hardware key.
Meter information is stored in a internal data prom, that secure data when the power disappear.
Information like the totalizer 1 and 2, date and time, and the statistic data in the Advanced version
is stored each 10 minutes. Every 4 hours is the battery consumption calculated and remain battery
capacity is updated together with „operation time since first power up“ and „battery operation
time“.
Data backup