MAG 8000 & MAG 8000 CT
45
SFIDK.PS.026.D9.02
1)
Lithium batteries are subject to special transportation regulations accord-ing to United Nations
"Regulation of Dangerous Goods, UN 3090 and UN 3091". Special transport documentation is required
to observe these regu-lations. This may influence both transport time and costs.
Communication
IrDA: Standard integrated infrared communication interface with
MODBUS RTU protocol
Add-on modules:
•
RS 232 serial interface with MODBUS RTU (Rx/Tx/GND),
point to point with max. 15 m cable
•
RS 485 serial interface with MODBUS RTU (+/-/GND),
multidrop with up to 32 devices with max. 1000 m cable
MODBUS RTU protocol is an open protocol (further information
available on request)
Serial speed 1200, 2400, 4800, 9600, 19200, 38400 Baud
Battery power supply
1)
Auto detection of power source with displayed symbol for remaining
power. In battery mode, excitation frequency is manually selected
Internal battery pack: 2 D-Cell 3.6 V / 33 Ah
External battery pack: 4 D-Cell 3.6 V / 66 Ah
12-24 V AC/DC power supply
Input voltage range: 12-24 V AC/DC (10-32 V AC/DC)
Power consumption during line: 2 VA
Isolation: Class II
Fuse: 1000 mA T - Not replaceable
Short circuit protection: Module is protected from short circuit on
the output connector. Both during mains and backup supply
Complies with standards: IEC 61010-1, OIML R49-1,
EN 61000-6-3, EN 610000-6-2
115/230 V AC mains power
Input voltage range: 115/230 V AC, +15% to
−
20%, 50-60 Hz
supply
Power consumption during mains: 2 VA
Isolation: Class II
Fuse: 250 mA T - Not replaceable
Short circuit protection: Module is protected from short circuit on
the output connector. Both during mains and backup supply
Complies with standards: IEC 61010-1, OIML R49-1,
EN 61000-6-3, EN 610000-6-2
Input cable for
Factory mounted PUR cable with 2 x 1 mm
2
12-24 V AC/DC and
(brown, blue), length = 3 m
115/230 V AC power supply
Resistant to sunlight and water
Outer diameter 7 mm
Rated voltage (V AC) 300/500 V AC
Testing voltage (V AC) 2000 V AC
Temperature range (°C):
Fixed laying
−
40 to +90 °C
Flexible application
−
30 to +80 °C
Minumum bending radius 28 mm, (fixed installation)
Maximum pulling force 200 N
Output: As battery connector - female
Backup battery: As battery connector - male
8. Technical data
(continued)
Содержание SITRANS F M MAG 8000
Страница 60: ...MAG 8000 MAG 8000 CT 60 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Страница 61: ...MAG 8000 MAG 8000 CT 61 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Страница 62: ...MAG 8000 MAG 8000 CT 62 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Страница 63: ...MAG 8000 MAG 8000 CT 63 SFIDK PS 026 D9 02 10 Approvals and certificates ...