Version
MAG 3100 P
MAG 3100
MAG 3100 HT
Ex approvals
Ex sensor DN 15 to 300:
• ATEX 2GD Ex de ia IIC T3 - T6
• IEC Ex de e ia IIC T3 - T6
• FM Class 1 Div 1 (only com‐
pact mounted)
• FM Class 1 Zone 1
• CSA Class 1 Zone 1
Standard sensors:
• FM Class 1 Div 2
• CSA Class 1, Div 2
Ex sensor DN 15 to 300:
• ATEX 2GD Ex de ia IIC T3 - T6
• IEC Ex e ia IIC T3 - T6
• FM Class 1 Div 1 (only com‐
pact mounted)
• FM Class 1 Zone 1
• CSA Class 1 Zone 1
DN 350 to 2000:
• Ex e ia IIC T4 - T6
• FM Class 1 zone 1
• CSA Class 1 zone 1
• IEC Ex de ia IIC T3-T6
• Ex tD A21 IP67
Standard sensors:
• FM Class 1 Div 2
• CSA Class 1, Div 2
Ex sensor DN 15 to 300:
• ATEX 2GD Ex de ia IIC T3 - T6
• IEC Ex de ia IIC T3-T6
• FM Class 1 zone 1
• CSA Class 1 zone 1
Standard sensors:
• FM Class 1 Div 2
• CSA Class 1, Div 2
Drinking water approvals
EPDM lining:
• WRAS (WRc, BS6920 cold wa‐
ter, GB)
• NSF/ANSI Standard 61 (Cold
water, US)
• ACS listed (F)
• DVGW W270 (D)
• Belgaqua (B)
• MCERTS (GB) (EPDM or PTFE
lining with AISI 316 or Hastel‐
loy electrodes)
Custody transfer (CT)
(≤ DN 2000)
(only with MAG
5000/6000 CT)
Cold water pattern approval:
• OIML R 49 (Denmark)
Cold water pattern approval:
• PTB (Germany)
Other media than water
• OIML R 117 (Denmark)
1) For sizes larger than 600 mm (24") in PN 16 PED conformity is available as a cost-added option. The basic unit will carry the LVD (Low Voltage Directive) and EMC approval.
Technical specifications
SITRANS FM MAG 3100
78
Operating Instructions, 12/2021, A5E03005599-AE