![Siemens SIPROTEC 7SD80 Скачать руководство пользователя страница 397](http://html.mh-extra.com/html/siemens/siprotec-7sd80/siprotec-7sd80_manual_382671397.webp)
Appendix
A.11 Measured Values
SIPROTEC, 7SD80, Manual
E50417-G1140-C474-A1, Release date 09.2011
397
7761
Relay ID of 1st. relay (Relay ID)
Measure Master
-
-
-
-
-
CFC
CD
DD
7762
I A (% of Operational nominal current) (I
A_opN=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7763
Angle I A_remote <-> I A_local (
Φ
I A=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7764
I B (% of Operational nominal current) (I
B_opN=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7765
Angle I B_remote <-> I B_local (
Φ
I B=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7766
I C (% of Operational nominal current) (I
C_opN=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7767
Angle I C_remote <-> I C_local (
Φ
I C=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7769
V A (% of Operational nominal voltage) (V
A_opN=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7770
Angle V A_remote <-> V A_local (
Φ
V A=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7771
V B (% of Operational nominal voltage) (V
B_opN=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7772
Angle V B_remote <-> V B_local (
Φ
V C=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7773
V C (% of Operational nominal voltage) (V
C_opN=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7774
Angle V C_remote <-> V C_local (
Φ
V C=)
Measure Master
-
-
-
-
-
CFC
CD
DD
7781
Relay ID of 2nd. relay (Relay ID)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7782
I A (% of Operational nominal current) (I
A_opN=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7783
Angle I A_remote <-> I A_local (
Φ
I A=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7784
I B (% of Operational nominal current) (I
B_opN=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7785
Angle I B_remote <-> I B_local (
Φ
I B=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7786
I C (% of Operational nominal current) (I
C_opN=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7787
Angle I C_remote <-> I C_local (
Φ
I C=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7789
V A (% of Operational nominal voltage) (V
A_opN=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7790
Angle V A_remote <-> V A_local (
Φ
V A=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7791
V B (% of Operational nominal voltage) (V
B_opN=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7792
Angle V B_rem <-> V B_local (
Φ
V B=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7793
V C (% of Operational nominal voltage) (V
C_opN=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
7794
Angle V C_remote <-> V C_local (
Φ
V C=)
Measure Slave
-
-
-
-
-
CFC
CD
DD
10102
Min. Zero Sequence Voltage 3V0 (3V0min =) Min/Max meter
-
-
-
-
-
CFC
CD
DD
10103
Max. Zero Sequence Voltage 3V0 (3V0max
=)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
32204
Output power of the FO-Interface = (Output-
Power FO=)
Measure PDI
-
-
-
-
-
CFC
CD
DD
32205
Input power of the FO-Interface = (Input
Power FO=)
Measure PDI
-
-
-
-
-
CFC
CD
DD
32206
Budget of the FO-Interface = (Budget FO =)
Measure PDI
-
-
-
-
-
CFC
CD
DD
32208
Attenuation of the Cu-Interface = (Attenua-
tionCu =)
Measure PDI
-
-
-
-
-
CFC
CD
DD
32209
Signal-to-noise ratio Cu-Interface = (StN
Ratio Cu=)
Measure PDI
-
-
-
-
-
CFC
CD
DD
32210
Send telegrams in the last second= (Send
Tel.sec=)
Measure PDI
-
-
-
-
-
CFC
CD
DD
32211
Good received telegrams in the last sec=
(Good Rec.sec=)
Measure PDI
-
-
-
-
-
CFC
CD
DD
No.
Description
Function
IEC 60870-5-103
Configurable in Matrix
Ty
p
e
Inf
o
rm
a
tion
Num
b
e
r
Com
p
a
ti
b
il
it
y
Da
ta
U
n
it
Po
si
ti
on
CFC
Cont
ro
l Dis
p
la
y
D
e
fa
u
lt D
is
p
la
y