Appendix
A.9 Information List
SIPROTEC, 7SD80, Manual
E50417-G1140-C474-A1, Release date 09.2011
377
383
>Enable all AR Zones / Elements
(>Enable ARzones)
P.System Data 2
SP
On
Off
On
Off
*
LED BI
BO
385
>Lockout SET (>Lockout SET)
P.System Data 2
SP
On
Off
*
*
LED BI
BO
150
35
1
Yes
386
>Lockout RESET (>Lockout
RESET)
P.System Data 2
SP
On
Off
*
*
LED BI
BO
150
36
1
Yes
395
>I MIN/MAX Buffer Reset (>I
MinMax Reset)
Min/Max meter
SP
ON
*
*
LED BI
BO
396
>I1 MIN/MAX Buffer Reset (>I1
MiMaReset)
Min/Max meter
SP
ON
*
*
LED BI
BO
397
>V MIN/MAX Buffer Reset (>V
MiMaReset)
Min/Max meter
SP
ON
*
*
LED BI
BO
398
>Vphph MIN/MAX Buffer Reset
(>VphphMiMaRes)
Min/Max meter
SP
ON
*
*
LED BI
BO
399
>V1 MIN/MAX Buffer Reset (>V1
MiMa Reset)
Min/Max meter
SP
ON
*
*
LED BI
BO
400
>P MIN/MAX Buffer Reset (>P
MiMa Reset)
Min/Max meter
SP
ON
*
*
LED BI
BO
401
>S MIN/MAX Buffer Reset (>S
MiMa Reset)
Min/Max meter
SP
ON
*
*
LED BI
BO
402
>Q MIN/MAX Buffer Reset (>Q
MiMa Reset)
Min/Max meter
SP
ON
*
*
LED BI
BO
403
>Idmd MIN/MAX Buffer Reset
(>Idmd MiMaReset)
Min/Max meter
SP
ON
*
*
LED BI
BO
404
>Pdmd MIN/MAX Buffer Reset
(>Pdmd MiMaReset)
Min/Max meter
SP
ON
*
*
LED BI
BO
405
>Qdmd MIN/MAX Buffer Reset
(>Qdmd MiMaReset)
Min/Max meter
SP
ON
*
*
LED BI
BO
406
>Sdmd MIN/MAX Buffer Reset
(>Sdmd MiMaReset)
Min/Max meter
SP
ON
*
*
LED BI
BO
407
>Frq. MIN/MAX Buffer Reset
(>Frq MiMa Reset)
Min/Max meter
SP
ON
*
*
LED BI
BO
408
>Power Factor MIN/MAX Buffer
Reset (>PF MiMaReset)
Min/Max meter
SP
ON
*
*
LED BI
BO
410
>52a Bkr1 aux. 3pClosed (for
AR,CB-Test) (>52a Bkr1 3p Cl)
P.System Data 2
SP
*
*
*
LED BI
BO
150
80
1
Yes
411
>52b Bkr1 aux. 3p Open (for
AR,CB-Test) (>52b Bkr1 3p Op)
P.System Data 2
SP
*
*
*
LED BI
BO
150
81
1
Yes
501
Relay PICKUP (Relay PICKUP)
P.System Data 2
OUT
*
*
M
LED
BO
192
84
2
Yes
502
Relay Drop Out (Relay Drop Out) P.System Data 2
OUT
503
Relay PICKUP Phase A (Relay
PICKUP ØA)
P.System Data 2
OUT
*
*
m
LED
BO
192
64
2
Yes
504
Relay PICKUP Phase B (Relay
PICKUP ØB)
P.System Data 2
OUT
*
*
m
LED
BO
192
65
2
Yes
505
Relay PICKUP Phase C (Relay
PICKUP ØC)
P.System Data 2
OUT
*
*
m
LED
BO
192
66
2
Yes
506
Relay PICKUP GROUND (Relay
PICKUP G)
P.System Data 2
OUT
*
*
m
LED
BO
192
67
2
Yes
510
Relay GENERAL CLOSE
command (Relay CLOSE)
P.System Data 2
OUT
*
*
*
LED
BO
511
Relay GENERAL TRIP command
(Relay TRIP)
P.System Data 2
OUT
*
OFF
M
LED
BO
192
68
2
No
530
LOCKOUT is active (LOCKOUT) P.System Data 2
IntSP
On
Off
*
*
LED
BO
533
Primary fault current Ia (Ia =)
P.System Data 2
VI
*
On
Off
150
177
4
No
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
a
u
lt)
Log ON
/O
FF
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on