Appendix
A.9 Information List
SIPROTEC, 7SD80, Manual
E50417-G1140-C474-A1, Release date 09.2011
380
2752
>79: External pickup 3phase for
AR start (>Pickup 3ph AR)
79 Auto Recl.
SP
*
ON
*
LED BI
BO
40
47
2
Yes
2781
79: Auto recloser is switched OFF
(79 OFF)
79 Auto Recl.
OUT
On
Off
*
*
LED
BO
40
81
1
Yes
2782
79: Auto recloser is switched ON
(79 ON)
79 Auto Recl.
IntSP
*
*
*
LED
BO
192
16
1
Yes
2783
79: Auto recloser is blocked (79 is
blocked)
79 Auto Recl.
OUT
On
Off
*
*
LED
BO
40
83
1
Yes
2784
79: Auto recloser is not ready (79
not ready)
79 Auto Recl.
OUT
*
ON
*
LED
BO
192
130
1
Yes
2787
79: Circuit breaker 1 not ready
(CB not ready)
79 Auto Recl.
OUT
*
*
*
LED
BO
40
87
1
Yes
2788
79: CB ready monitoring window
expired (79 T-CBreadyExp)
79 Auto Recl.
OUT
*
ON
*
LED
BO
40
88
2
Yes
2796
79: Auto recloser ON/OFF via BI
(79 on/off BI)
79 Auto Recl.
IntSP
*
*
*
LED
BO
2801
79 - in progress (79 in progress)
79 Auto Recl.
OUT
*
ON
*
LED
BO
40
101
2
Yes
2809
79: Start-signal monitoring time
expired (79 T-Start Exp)
79 Auto Recl.
OUT
*
ON
*
LED
BO
40
174
2
Yes
2810
79: Maximum dead time expired
(79 TdeadMax Exp)
79 Auto Recl.
OUT
*
ON
*
LED
BO
40
175
2
Yes
2818
79: Evolving fault recognition (79
Evolving Flt)
79 Auto Recl.
OUT
*
ON
*
LED
BO
40
118
2
Yes
2821
79 dead time after evolving fault
(79 Td. evol.Flt)
79 Auto Recl.
OUT
*
On
Off
*
LED
BO
40
197
2
Yes
2840
79 dead time after 3pole trip
running (79 Tdead 3pTrip)
79 Auto Recl.
OUT
*
ON
*
LED
BO
40
149
2
Yes
2843
79 dead time after 3phase fault
running (79 Tdead 3pFlt)
79 Auto Recl.
OUT
*
ON
*
LED
BO
40
154
2
Yes
2844
79 1st cycle running (79 1stCyc.
run.)
79 Auto Recl.
OUT
*
ON
*
LED
BO
40
155
2
Yes
2845
79 2nd cycle running (79 2ndCyc.
run.)
79 Auto Recl.
OUT
*
ON
*
LED
BO
40
157
2
Yes
2851
79 - Close command (79 Close)
79 Auto Recl.
OUT
*
ON
m
LED
BO
192
128
2
No
2853
79: Close command after 3pole,
1st cycle (79 Close1.Cyc3p)
79 Auto Recl.
OUT
*
*
*
LED
BO
40
153
1
Yes
2854
79: Close command 2nd cycle
(and higher) (79 Close 2.Cyc)
79 Auto Recl.
OUT
*
*
*
LED
BO
192
129
1
No
2861
79: Reclaim time is running (79 T-
Recl. run.)
79 Auto Recl.
OUT
*
*
*
LED
BO
40
161
1
Yes
2862
79 - cycle successful (79 Suc-
cessful)
79 Auto Recl.
OUT
*
*
*
LED
BO
40
162
1
Yes
2871
79: TRIP command 3pole (79
TRIP 3pole)
79 Auto Recl.
OUT
*
ON
*
LED
BO
40
171
2
Yes
2889
79 1st cycle zone extension
release (79 1.CycZoneRel)
79 Auto Recl.
OUT
*
*
*
LED
BO
40
160
1
Yes
2890
79 2nd cycle zone extension
release (79 2.CycZoneRel)
79 Auto Recl.
OUT
*
*
*
LED
BO
40
169
1
Yes
2894
79 Remote close signal send (79
Remote Close)
79 Auto Recl.
OUT
*
ON
*
LED
BO
40
129
2
Yes
2896
No. of 1st AR-cycle CLOSE com-
mands,3pole (79 #Close1./3p=)
Statistics
VI
2898
No. of higher AR-cycle CLOSE
commands,3p (79 #Close2./3p=)
Statistics
VI
3102
Tolerance invalid in phase A (2nd
Harmonic A)
InRushRestraint
OUT
*
*
LED
BO
92
89
1
Yes
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
a
u
lt)
Log ON
/O
FF
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on