5. Remove the shield contact. See also: Protective conductor connection and shield contact
(Page 122)
6. Slide the lug downwards and swivel the module to the front in order to remove it.
Note
The 50 mm ventilation clearances above and below the components must be observed.
4.18.4
This is how you install a TM54F
Installing
Procedure:
1. Place the component on the mounting rail.
2. Then, swivel the component on the mounting rail so that the mounting catches click into
place at the rear.
3. Slide the component along the mounting rail to either the left or right up to its final position.
4. Screw on the protective conductor connection.
5. If necessary, screw on the shield connection.
6. Insert the connectors for the digital inputs and outputs at X520 - X535.
7. Insert the DRIVE-CLiQ cables at X500 and X501.
8. Insert the connectors for the sensor and electronics power supply at X514 and X524.
Note
The 50 mm ventilation clearances above and below the components must be observed.
4.18.5
TM120 status displays
Status displays
The Terminal Module TM120 has the following status displays, which provide information about
the module state:
State
Description, cause
Remedy
RDY
-
Off
Electronics power supply is missing or outside permissible toler‐
ance range.
Check the power sup‐
ply.
Green
Continuous
light
The component is ready for operation and cyclic DRIVE-CLiQ com‐
munication is taking place.
--
Orange
Continuous
light
DRIVE-CLiQ communication is being established.
--
Service cases - hardware
4.18 Terminal Modules
Software and hardware
224
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
Содержание SINUMERIK 828D Turning
Страница 9: ...Index 245 Table of contents Software and hardware Service Manual 08 2018 6FC5397 5DP40 6BA1 9 ...
Страница 10: ...Table of contents Software and hardware 10 Service Manual 08 2018 6FC5397 5DP40 6BA1 ...
Страница 244: ...Appendix A 3 Documentation overview SINUMERIK 828D Software and hardware 244 Service Manual 08 2018 6FC5397 5DP40 6BA1 ...