4. Release the Torx screws and connect the DC link busbar.
7RU[7
5. Tighten the Torx screws of the DC link busbars, observe the correct sequence.
7RU[7
7RU[7
6. Place the red jumper plug on the electronics busbar until it clicks into place.
7. Place the 24 V terminal adapter on the electronics power supply busbar until it clicks into
place.
8. Close the protective cover of the DC link voltage.
9. Reconnect motor connections X1 and X2 - if available - to the module.
10.Insert the DRIVE-CLiQ cables that were previously withdrawn into sockets X200 - X202.
Service cases - hardware
4.13 Double Motor Modules
Software and hardware
186
Service Manual, 08/2018, 6FC5397-5DP40-6BA1