Figure 4-12
Switch S2
Switch S2 defines the IP address of the machine control panel:
1
2
3
4
5
6
7
8
9
10
Device name
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
PROFINET address "64"
For SINUMERIK 828D, the IP address = 192.168.214.64 must always be assigned to the MCP.
4.5.9
Status displays MCP 310C PN
LEDs for status display
For the MCP 310C PN there are 3 LEDs in a row (H1-H3), which provide information about
the module state:
6
+ + +
Figure 4-13
Status displays
LED
H1 (green)
PowerOK
H2 (green)
PN Sync
H3 (red)
PN Fault
Power OFF
OFF
OFF
OFF
Power ON (voltage is stable)
ON
OFF
OFF
Boot software runs and loads the system software
ON
ON
ON
System software starts
ON
OFF
OFF
System software runs, no communication to the con‐
troller
ON
OFF
OFF
System software runs, communication to the control‐
ler, STOP state
ON
ON
OFF
System software runs, communication to the control‐
ler, RUN state
ON
Flashes at
0.5 Hz
OFF
Service cases - hardware
4.5 Machine control panels
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
103