5. If it has not already been done, label all connectors and cables that lead to the module now.
Only then, can it be ensured that the cables are not interchanged.
6. Withdraw the electronics power supply X124.
7. Withdraw the digital input/output terminal X122.
8. Withdraw any connected DRIVE-CLiQ cables X100 - X103.
9. Remove the protective conductor connection of the NX10.3 / NX15.3.
10.Release the screws attaching the NX10.3 / NX15.3 to the mounting plate.
– OR –
11.If the module is located to the left of the infeed, remove the module by first pulling it upwards
and then removing it towards the left.
4.7.4
This is how you install the NX10.3 / NX15.3
Installing
Procedure:
1. Screw the new NX10.3 / NX15.3 to the mounting plate.
– OR –
2. If the module was located to the left of the infeed, re-attach it here by first introducing the
NX10.3 / NX15.3 into the holder to the right and then press it down slightly to retain it.
3. Reconnect the protective conductor connection of the NX10.3 / NX15.3.
4. Insert the DRIVE-CLiQ cables that were previously withdrawn into sockets X100-X103.
5. Insert the digital input/output terminal X122 into the NX10.3 / NX15.3.
6. Reconnect the electronics power supply X124.
7. Now check that all of the cables have been reconnected.
8. Now close the cover of the NX10.3 / NX15.3.
9. Close the cabinet and switch-on the system again.
Service cases - hardware
4.7 Expansion modules NX10.3 / NX15.3
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1