Getting connected to MindSphere
6.6 Parameter list
SINAMICS CONNECT
76
Operating Instructions, 10/2018, A5E45421408
6.6
Parameter list
The parameter list provides an overview of the parameter data that SINAMICS CONNECT
can collect from the converters and upload to MindSphere for further analysis. With the
parameter number, you can refer to converter specific documentation for more details of
each parameter.
To create aspects and variables in Asset Manager, you have to follow this parameter list. For
each aspect (eight aspects in total), you need to add the variables one by one as per the
name, unit, and data type of each parameter (one entry for one variable). For more
information about how to add variables, see Section "Creating aspects and variables
(Page 62)".
Pa-
rame-
ter ID
Parameter No.
Name
Description
Unit Data
type
1)
Sam-
pling
cycle
Activa-
tion
status
V20
MM440 G120
1
r0026
r0026
r0026
portX_Act_filtered_DC_link
_volt
2)
Displays filtered DC-link
voltage
V
Double 5 s
Active
2
r0025
r0025
r0025
portX_Act_filtered_output_
voltage
Displays filtered [rms]
voltage applied to motor
V
Double 5 s
Active
3
r0032
r0032
r0032
portX_Act_filtered_power Displays (mechanical)
shaft power
kW
Double 5 s
Active
4
r0022
r0022
r0022
portX_Act_filtered_rotor_s
peed
Displays calculated
rotor speed based on
r0021
rpm Double 5 s
Active
5
r0031
r0031
r0031
portX_Act_filtered_torque Displays electrical
torque
NM
Double 5 s
Active
6
r0039[0]
3)
r0039[0] r0039[0] portX_Energy_consumpt_
meter
Displays electrical en-
ergy used by converter
since display was last
reset
kWh Double 5 s
Active
7
r0207[0] r0207[0] r0207[0] portX_Rated_converter_cu
rrent
Displays rated converter
current
A
Double 5 s
Active
8
p0305[0] p0305[0] p0305[0] portX_Rated_motor_curre
nt
Nominal motor current
from rating plate
A
Double 5 s
Active
9
r0002
r0002
r0002
portX_Converter_state
Displays actual con-
verter state
-
Double 5 s
Active
10
r0018
r0018
r0018
portX_Firmware_version
Displays version num-
ber of installed firmware
-
Double 5 s
Active
11
_ 4)
r0030
r0030
portX_CO_Act_filtered_cur
rent_Isq
Displays torque-
generating current
component
A
Double 5 s
Active
12
r0037[0] r0037[0] r0037[0] portX_CO_Converter_tem
perature
Heat sink temperature degC Double 5 s
Active
13
r0035[0] r0035[0] r0035[0] portx_CO_Act_motor_tem
perature
Displays calculated
motor temperature
degC Double 5 s
Active
14
r0947[0] r0947[0] r0945[0] portX_Fault_code_1
Recent fault trip 1
-
Double 5 s
Active
15
r0947[1] r0947[1] r0945[1] portX_Fault_code_2
Recent fault trip 2
-
Double 5 s
Active
16
r0947[2] r0947[2] r0945[2] portX_Fault_code_3
Recent fault trip 3
-
Double 5 s
Active
17
r0947[3] r0947[3] r0945[3] portX_Fault_code_4
Recent fault trip 4
-
Double 5 s
Active