Configuring the device
5.2 Standard Web pages
SINAMICS CONNECT
52
Operating Instructions, 10/2018, A5E45421408
7.
The Web browser jumps back to the port configuration home page. Click “Parameters” to
start setting converter parameters.
8.
In the window that opens, activate (for example) parameter 1 via the check box.
9.
Set the sampling period (an integer equal to or greater than 1) in the "Sample Cycle"
input field. The period is measured in seconds.
(Repeat steps 8 and 9 to set the remaining parameters as desired.)
10.
Click “Save” to activate the parameter settings or click “Close” to cancel the settings.
Note: Clicking “Default” resets all the parameters to their default settings in the predefined
parameter list (Page 76).
11.
The Web browser jumps back to the port configuration home page.
(Repeat steps 2 to 10 to configure other ports as desired.)
12.
The Web browser jumps back to the port configuration home page. Click "View
Modifications" in the lower-right corner to view the port configuration results.
–
Button a: jumps back to the port configuration home page for you to make further
modifications.
–
Button b: discards all the settings and brings you back to the home page.
–
Button c: saves all the settings in the SD card of the device and jumps back to the
home page.
Note: After you click button b or c, a pop-up box displays, asking whether to continue the
operation.