Technical Data
12.96
9-6
Siemens AG 6SE7087-6BM70
SIMOVERT MASTER DRIVES Operating Instructions
Inverter types
6SE70... 41-0WM20 41-1WM20 41-2WM20 41-4WM20 41-6WM20
Rated voltage, rated frequency, rated current, rated output
Rated voltage in V
n
Input
Output
V
DC 890...930 ±15 %
3 AC 0 ... Rated voltage / 1.35
Rated frequency f
n
Input
Output:
U/f = konst
U = konst
Hz
0 ... 600
8 ... 300
Rated current I
n
Input
Output
A
1178
990
1285
1080
1464
1230
1666
1400
1880
1580
DC link voltage V
dn
V
= Rated voltage
Rated output
kVA
1132..1183 1235..1291 1406..1470 1600..1673 1806..1888
Auxiliary power supply
DC 24 V (20 V - 30 V)
A
5 + 3 without Options;
with Options refer to Section 6.1
Auxiliary power supply
V
AC 230
±
15%
Loading Class II acc. to EN 60146-1-1
Rated current
A
901
983
1119
1274
1438
Base load time
s
240
Overcurrent
A
1346
1469
1673
1904
2149
Overcurrent time
s
60
Losses, cooling, power factor
Power factor
Converter cos
ϕ
U
<
0.92 ind.
<
0.92 ind.
<
0.92 ind.
<
0.92 ind.
<
0.92 ind.
Efficiency
η
−
Pulse frequency 2.5 kHz
0.98
0.98
0.98
0.98
0.98
Power loss
−
Pulse frequency 2.5 kHz
kW
16
20
23.9
29
33.3
Required cooling air flow
m
3
/s
1.5
1.5
1.5
1.7
1.7
Pressure drop
∆
p
Pa
640
640
640
950
950
Sound pressure level, dimensions, weights
Sound pressure level
dB(A)
85
85
85
88
88
Type
M
M
M
M
M
Width
Height
Depth
mm
2300
1910
580
2300
1910
580
2300
1910
580
2300
1910
580
2300
1910
580
Ground
−
IP00
kg
ca. 1500
ca. 1500
ca. 1500
ca. 1500
ca. 1500
Required current for fan (typical)
230 V / 50 Hz
A
10.4
10.4
10.4
26.8
26.8
230 V / 60 Hz
A
13.4
13.4
13.4
40.0
40.0