Spare parts
10
10.1
Ordering data
When ordering spare parts, in addition to the precise designation of the spare part, specify the
motor type and the serial number of the motor. Ensure that the spare part designation matches
the designation in the spare part lists and add the associated part number.
Example:
Bearing shield, drive end (Part 105)
Machine type DNGW-315ML-04A
Serial numberLDX/30000001
The machine type and serial number can be found on the rating plate data and in the technical
data. The serial number is also stamped on the end face of the shaft extension at the drive
end.
10.2
Replacing roller bearings
Rolling-contact bearings
When ordering roller bearings, in addition to the bearing identification code, the supplementary
specifying code is also necessary for the bearing version. Both of these codes are stamped
on the lubricant plate and specified in the motor documentation, or can also be taken from the
installed bearings.
If roller-contact bearings with an insulated design are installed, use roller bearings of the same
type as spare parts. This will prevent any bearing damage being caused by bearing currents.
SIMOTICS XP 1MD4/1MD5
Operating Instructions 05/2015
91
Содержание SIMOTICS XP 1MD4
Страница 2: ...13 07 2015 11 26 V8 00 ...
Страница 10: ...Table of contents SIMOTICS XP 1MD4 1MD5 10 Operating Instructions 05 2015 ...
Страница 12: ...Introduction SIMOTICS XP 1MD4 1MD5 12 Operating Instructions 05 2015 ...
Страница 20: ...Safety notes 2 11 Ventilation SIMOTICS XP 1MD4 1MD5 20 Operating Instructions 05 2015 ...
Страница 26: ...Description SIMOTICS XP 1MD4 1MD5 26 Operating Instructions 05 2015 ...
Страница 40: ...Preparations for use 4 10 Converter operation SIMOTICS XP 1MD4 1MD5 40 Operating Instructions 05 2015 ...
Страница 50: ...Assembling 5 3 Installing the machine SIMOTICS XP 1MD4 1MD5 50 Operating Instructions 05 2015 ...
Страница 74: ...Operation 8 7 Faults SIMOTICS XP 1MD4 1MD5 74 Operating Instructions 05 2015 ...
Страница 90: ...Maintenance 9 2 Repair SIMOTICS XP 1MD4 1MD5 90 Operating Instructions 05 2015 ...
Страница 110: ...Disposal 11 4 Disposal of components SIMOTICS XP 1MD4 1MD5 110 Operating Instructions 05 2015 ...
Страница 126: ...Index SIMOTICS XP 1MD4 1MD5 126 Operating Instructions 05 2015 ...
Страница 127: ...AE EC Declaration of Conformity U161 AD EC Declaration of Conformity U163 AA R No 20000h U165 ...
Страница 128: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...