Machines with Ex t type of protection can be marked as follows:
Table 3-2
Marking for machines with Ex tb type of protection for zone 21
Directive
Ex marking
Directive 94/9/EC with EC type-examination certificate
0102
II 2D Ex tb IIIC T... °C Db
0102
II 2D Ex tb IIIB T... °C Db
0102
II 2D Ex tb IIIA T... °C Db
IECEx-Scheme With Certificate of Conformity
Ex tb IIIC T... °C Db
Ex tb IIIB T... °C Db
Ex tb IIIA T... °C Db
Table 3-3
Marking for machines with Ex tc type of protection for Zone 22 without certificate
Directive
Ex marking
Directive 94/9/EC
II 3D Ex tc IIIC T... °C Dc
II 3D Ex tc IIIB T... °C Dc
II 3D Ex tc IIIA T... °C Dc
IECEx-Scheme with Certificate of Conformity
Ex tc IIIC T... °C Dc
Ex tc IIIB T... °C Dc
Ex tc IIIA T... °C Dc
Machine design
The regulations and standards used as the basis to design and test this machine are stamped
on the rating plate.
The machine design basically complies with the subsequent standards. Please refer to the EC
Declaration of Conformity for the versions of the harmonized standards referenced.
Table 3-4
Machine design
Feature
Standard
Rating and performance
IEC/EN 60034‑1
Degree of protection
IEC/EN 60034‑5
Cooling
IEC/EN 60034‑6
Type of construction
IEC/EN 60034‑7
Terminal markings and direction of rotation
IEC/EN 60034‑8
Noise emission
IEC/EN 60034‑9
Starting characteristics, rotating electrical machines
IEC/EN 60034‑12*
Vibration severity grades
IEC/EN 60034‑14
Vibration limits
DIN ISO 10816-3
* For machines in line operation only
Description
SIMOTICS XP 1MD4/1MD5
Operating Instructions 05/2015
23
Содержание SIMOTICS XP 1MD4
Страница 2: ...13 07 2015 11 26 V8 00 ...
Страница 10: ...Table of contents SIMOTICS XP 1MD4 1MD5 10 Operating Instructions 05 2015 ...
Страница 12: ...Introduction SIMOTICS XP 1MD4 1MD5 12 Operating Instructions 05 2015 ...
Страница 20: ...Safety notes 2 11 Ventilation SIMOTICS XP 1MD4 1MD5 20 Operating Instructions 05 2015 ...
Страница 26: ...Description SIMOTICS XP 1MD4 1MD5 26 Operating Instructions 05 2015 ...
Страница 40: ...Preparations for use 4 10 Converter operation SIMOTICS XP 1MD4 1MD5 40 Operating Instructions 05 2015 ...
Страница 50: ...Assembling 5 3 Installing the machine SIMOTICS XP 1MD4 1MD5 50 Operating Instructions 05 2015 ...
Страница 74: ...Operation 8 7 Faults SIMOTICS XP 1MD4 1MD5 74 Operating Instructions 05 2015 ...
Страница 90: ...Maintenance 9 2 Repair SIMOTICS XP 1MD4 1MD5 90 Operating Instructions 05 2015 ...
Страница 110: ...Disposal 11 4 Disposal of components SIMOTICS XP 1MD4 1MD5 110 Operating Instructions 05 2015 ...
Страница 126: ...Index SIMOTICS XP 1MD4 1MD5 126 Operating Instructions 05 2015 ...
Страница 127: ...AE EC Declaration of Conformity U161 AD EC Declaration of Conformity U163 AA R No 20000h U165 ...
Страница 128: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...