4.7
Protection against impermissible temperature rise
Every machine must be protected against an inadmissible temperature rise. Observe the
following notes:
● Protect every machine according to IEC / EN 60079–14 using a current-dependent,
delayed, circuit breaker with phase failure protection corresponding to IEC / EN 60947 or
a similar device in all phases.
● Set the protective device to the rated current (value is stamped on the rating plate).
● Select the protective device so that the motor is thermally protected even with a locked
rotor.
● For explosion-protected electrical machines with type protection "Increased safety", also
monitor the starting (starting monitoring with EC type examination certificate according to
Directive 94/9/EC or IECEx–Scheme with Certificate of Conformity). When the rotor is
locked, the protective device must trip within the tE time (safe locked rotor time). This
requirement is satisfied if the tripping time is not longer than the specified tE time.
● Protect the windings in a delta connection in such a way that the tripping unit or relay is
connected in series with the winding phases. When selecting and setting the tripping unit,
define the rated value of the phase current. The phase current is 0.58 times the rated motor
current. Any thermal motor protection via direct temperature monitoring to be used in
addition to the motor starter protector is stated on the rating plate if required.
4.8
System-inherent frequencies
NOTICE
Machine damage caused by system resonances
The system consisting of the foundation and machine set must be configured and matched
in such a way that no system resonances can arise and result in the permissible vibration
levels being exceeded. Excessive vibrations can damage the machine set. The vibration limit
values according to DIN ISO 10816-3 must not be exceeded.
4.9
Transport and storage
4.9.1
Transport markings
The packing differs depending on the transport type and size. If not otherwise contractually
agreed, the packaging corresponds to the packing guidelines for International Standards for
Phytosanitary Measures (ISPM).
Preparations for use
4.9 Transport and storage
SIMOTICS XP 1MD4/1MD5
Operating Instructions 05/2015
29
Содержание SIMOTICS XP 1MD4
Страница 2: ...13 07 2015 11 26 V8 00 ...
Страница 10: ...Table of contents SIMOTICS XP 1MD4 1MD5 10 Operating Instructions 05 2015 ...
Страница 12: ...Introduction SIMOTICS XP 1MD4 1MD5 12 Operating Instructions 05 2015 ...
Страница 20: ...Safety notes 2 11 Ventilation SIMOTICS XP 1MD4 1MD5 20 Operating Instructions 05 2015 ...
Страница 26: ...Description SIMOTICS XP 1MD4 1MD5 26 Operating Instructions 05 2015 ...
Страница 40: ...Preparations for use 4 10 Converter operation SIMOTICS XP 1MD4 1MD5 40 Operating Instructions 05 2015 ...
Страница 50: ...Assembling 5 3 Installing the machine SIMOTICS XP 1MD4 1MD5 50 Operating Instructions 05 2015 ...
Страница 74: ...Operation 8 7 Faults SIMOTICS XP 1MD4 1MD5 74 Operating Instructions 05 2015 ...
Страница 90: ...Maintenance 9 2 Repair SIMOTICS XP 1MD4 1MD5 90 Operating Instructions 05 2015 ...
Страница 110: ...Disposal 11 4 Disposal of components SIMOTICS XP 1MD4 1MD5 110 Operating Instructions 05 2015 ...
Страница 126: ...Index SIMOTICS XP 1MD4 1MD5 126 Operating Instructions 05 2015 ...
Страница 127: ...AE EC Declaration of Conformity U161 AD EC Declaration of Conformity U163 AA R No 20000h U165 ...
Страница 128: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...