Regreasing
The spent grease chamber is designed to accommodate the spent grease for a computed,
rated service life of 40000 operating hours.
● Clean the grease nipples before regreasing and then gradually press in an appropriate type
and amount of grease, as described on the lubricant plate. The shaft must then be rotated
so that the new grease can be distributed throughout the roller bearing. The roller bearing
temperature rises sharply at first, then drops to the normal value again after the excess
grease has been displaced out of the bearing.
– If the machine is fitted with grease removal sliders :
After the bearings have been regreased, with the motor running, the used grease should
be removed by pulling the slider fitted to the bearing to its stop several times.
– If the machine is fitted with grease collection chambers :
Unbolt the grease collection chambers at the intervals shown on the notice plate with
the motor stopped, and remove the used bearing grease. If this is not done, the grease
will clog and the bearings will overheat.
WARNING
Rotor can fall out
If the machine is in a vertical position, the rotor can fall out while work is being performed
on the locating bearing. This can result in death, serious injury or material damage.
Support or relieve the rotor when carrying out work with the machine in a vertical
position.
Grease types
For the standard operating range, a grease for temperatures down to ‑20 °C is normally used
for the initial greasing of roller bearings. If the machine has been ordered for use in the
extended temperature range of below ‑20 °C, the permissible type of grease is indicated on
the lubricant plate.
Note
Grease quantity control
The grease quantity control only operates correctly if the specified greases are used. This is
specified on plates attached to the machine.
Maintenance
9.1 Inspection and maintenance
SIMOTICS XP 1MD4/1MD5
84
Operating Instructions 05/2015
Содержание SIMOTICS XP 1MD4
Страница 2: ...13 07 2015 11 26 V8 00 ...
Страница 10: ...Table of contents SIMOTICS XP 1MD4 1MD5 10 Operating Instructions 05 2015 ...
Страница 12: ...Introduction SIMOTICS XP 1MD4 1MD5 12 Operating Instructions 05 2015 ...
Страница 20: ...Safety notes 2 11 Ventilation SIMOTICS XP 1MD4 1MD5 20 Operating Instructions 05 2015 ...
Страница 26: ...Description SIMOTICS XP 1MD4 1MD5 26 Operating Instructions 05 2015 ...
Страница 40: ...Preparations for use 4 10 Converter operation SIMOTICS XP 1MD4 1MD5 40 Operating Instructions 05 2015 ...
Страница 50: ...Assembling 5 3 Installing the machine SIMOTICS XP 1MD4 1MD5 50 Operating Instructions 05 2015 ...
Страница 74: ...Operation 8 7 Faults SIMOTICS XP 1MD4 1MD5 74 Operating Instructions 05 2015 ...
Страница 90: ...Maintenance 9 2 Repair SIMOTICS XP 1MD4 1MD5 90 Operating Instructions 05 2015 ...
Страница 110: ...Disposal 11 4 Disposal of components SIMOTICS XP 1MD4 1MD5 110 Operating Instructions 05 2015 ...
Страница 126: ...Index SIMOTICS XP 1MD4 1MD5 126 Operating Instructions 05 2015 ...
Страница 127: ...AE EC Declaration of Conformity U161 AD EC Declaration of Conformity U163 AA R No 20000h U165 ...
Страница 128: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...