Reinforced roller bearings
Size
Grease stability time for permanent lubrication or relubrication interval
for a regreasing system in operating hours at rated speed
Grease quantity for relu‐
brication in g per bearing
Horizontal type of construction (B)
Vertical type of construction (V)
3000
rpm
1500
rpm
≤1000
rpm
3000
rpm
1500
rpm
≤1000
rpm
3000
rpm
≤1500
rpm
180
2800
5600
8000
2000
4000
5600
17
17
200
20
20
225
25
25
250
2000
1400
2800
4000
25
25
280
4000
5600
25
35
315
35
25
355
2800
35
50
The specified relubrication intervals are valid for maximum ambient temperatures of 40 °C.
Reduce the relubrication intervals for a
10°C increase in temperature by a factor of 0.7 of the value listed in the table (max. 20
°C = factor 0.5). Times for operation on 60 Hz systems on request.
9.1.7.5
Grease stability times and fill quantities
The details for the grease stability times and relubrication intervals are stated on the lubrication
rating plate of the machine. The specified grease stability time applies to the ambient
temperature range stated on the rating plate. Reduce the lubrication interval for a 10° C
increase in temperature by a factor of 0.7 of the value listed in the table (max. 20° C = factor
0.5). Irrespective of the operating hours, the roller bearing grease and the bearing (2Z bearing)
must be replaced after four years of service.
9.1.7.6
Regreasing intervals and types of grease for operating rolling-contact bearings
Regreasing intervals
The regreasing intervals for roller bearings in operating hours and the grease types are stated
on the machine's lubricant plate. Regardless of the actual number of operating hours reached,
the machine must be regreased at least once a year. The lubrication information can be found
on the lubricant plate.
Note
Observe the regreasing intervals for the roller bearings
The regreasing intervals for roller bearings are different from the service/inspection intervals
for the machine. Failure to regrease the roller bearings at the specified intervals can result in
bearing damage.
Maintenance
9.1 Inspection and maintenance
SIMOTICS XP 1MD4/1MD5
Operating Instructions 05/2015
83
Содержание SIMOTICS XP 1MD4
Страница 2: ...13 07 2015 11 26 V8 00 ...
Страница 10: ...Table of contents SIMOTICS XP 1MD4 1MD5 10 Operating Instructions 05 2015 ...
Страница 12: ...Introduction SIMOTICS XP 1MD4 1MD5 12 Operating Instructions 05 2015 ...
Страница 20: ...Safety notes 2 11 Ventilation SIMOTICS XP 1MD4 1MD5 20 Operating Instructions 05 2015 ...
Страница 26: ...Description SIMOTICS XP 1MD4 1MD5 26 Operating Instructions 05 2015 ...
Страница 40: ...Preparations for use 4 10 Converter operation SIMOTICS XP 1MD4 1MD5 40 Operating Instructions 05 2015 ...
Страница 50: ...Assembling 5 3 Installing the machine SIMOTICS XP 1MD4 1MD5 50 Operating Instructions 05 2015 ...
Страница 74: ...Operation 8 7 Faults SIMOTICS XP 1MD4 1MD5 74 Operating Instructions 05 2015 ...
Страница 90: ...Maintenance 9 2 Repair SIMOTICS XP 1MD4 1MD5 90 Operating Instructions 05 2015 ...
Страница 110: ...Disposal 11 4 Disposal of components SIMOTICS XP 1MD4 1MD5 110 Operating Instructions 05 2015 ...
Страница 126: ...Index SIMOTICS XP 1MD4 1MD5 126 Operating Instructions 05 2015 ...
Страница 127: ...AE EC Declaration of Conformity U161 AD EC Declaration of Conformity U163 AA R No 20000h U165 ...
Страница 128: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...