Mechanical mounting
4.5 Balancing for "Premium Performance" bearing version
1PH808/1PH810 main motors
60
Operating Instructions, 04/2017, 610.48004.40f
4.5
Balancing for "Premium Performance" bearing version
The on-site mechanical system vibration characteristics depend on factors such as the
output elements, mounting situation, alignment, installation, and external vibration and can
increase the level of motor vibration. Under certain circumstances, the rotor may have to be
balanced completely with the output element.
1PH8 motors are supplied with "special" vibration severity. Mounting a coupling element on
the shaft extension changes the rotor balancing state. As a consequence, after mounting
coupling elements, the rotor must be completely balanced. The following description shows,
using an example, the procedure for 1PH8 motors with "Premium Performance" bearing
version. You must determine the vibration severity and the position of the imbalance by
making the appropriate measurements. You can then remove the imbalance.
Measuring unit required
2-channel vibration measuring unit
Frequency bandwidth: 10 Hz to 1000 Hz
The measuring unit must be equipped with a function to analyze orders of frequency
components. Using this function, you can display the imbalance (1st order vibration
component).
Содержание SIMOTICS M-1PH8
Страница 1: ......
Страница 2: ......
Страница 8: ...Introduction 1PH808 1PH810 main motors 8 Operating Instructions 04 2017 610 48004 40f ...
Страница 12: ...Table of contents 1PH808 1PH810 main motors 12 Operating Instructions 04 2017 610 48004 40f ...
Страница 40: ...Description 2 4 Structure 1PH808 1PH810 main motors 40 Operating Instructions 04 2017 610 48004 40f ...
Страница 118: ...Commissioning 6 6 Cooling 1PH808 1PH810 main motors 118 Operating Instructions 04 2017 610 48004 40f ...
Страница 124: ...Operation 7 2 Non operational periods 1PH808 1PH810 main motors 124 Operating Instructions 04 2017 610 48004 40f ...
Страница 144: ...Maintenance 8 2 Corrective maintenance 1PH808 1PH810 main motors 144 Operating Instructions 04 2017 610 48004 40f ...
Страница 147: ...Spare parts 1PH808 1PH810 main motors Operating Instructions 04 2017 610 48004 40f 147 Figure 9 1 Spare parts example ...
Страница 148: ...Spare parts 1PH808 1PH810 main motors 148 Operating Instructions 04 2017 610 48004 40f ...
Страница 185: ......
Страница 186: ......