Mechanical mounting
4.5 Balancing for "Premium Performance" bearing version
1PH808/1PH810 main motors
62
Operating Instructions, 04/2017, 610.48004.40f
2.
Make a reference mark on the shaft (DE) for the speed and angle detection.
3.
Position the measuring sensors: Sensor 1 for the DE, sensor 2 for the NDE.
4.
Perform the reference measurement on the freely suspended motor for the DE and the
NDE. Measure the absolute value and angular position of the imbalance (1st order).