Connection
5.2 Electrical connection
1PH808/1PH810 main motors
Operating Instructions, 04/2017, 610.48004.40f
99
5.2.11
Connecting the external fan on 1PH808
The fan connection is a size 1 power connector.
Table 5- 4
Connection specifications for external fans with 1PH808
Air flow
direction
Max. current consumption at
230 V / 50 Hz (±10 %)
[A]
230 V / 60 Hz (±10 %)
[A]
265 V / 60 Hz (±10 %)
[A]
NDE --> DE
0.33
0.25
0.32
DE --> NDE
0.20
0.16
0.19
Note the following information regarding connections:
●
Only use cables that comply with the relevant installation regulations regarding voltage,
current, insulation material, and load-carrying capacity.
●
Before connecting the device, make sure that the line voltage matches the device
voltage.
●
Check whether the data on the fan rating plate matches the connection data.
●
Connection cables must not be subject to excessive tensile stress.
NOTICE
Damage to the fan when inappropriately operated
The fan can be destroyed if inappropriately operated.
•
Use blocking protection (stall protection) to protect the fan against inappropriate
operation. To do this, use a suitable motor circuit breaker where all poles can be
disconnected. Operate the fan using this circuit breaker.
•
Provide an interlocking circuit that prevents the main motor from being switched on
when the fan unit is not operational.
Содержание SIMOTICS M-1PH8
Страница 1: ......
Страница 2: ......
Страница 8: ...Introduction 1PH808 1PH810 main motors 8 Operating Instructions 04 2017 610 48004 40f ...
Страница 12: ...Table of contents 1PH808 1PH810 main motors 12 Operating Instructions 04 2017 610 48004 40f ...
Страница 40: ...Description 2 4 Structure 1PH808 1PH810 main motors 40 Operating Instructions 04 2017 610 48004 40f ...
Страница 118: ...Commissioning 6 6 Cooling 1PH808 1PH810 main motors 118 Operating Instructions 04 2017 610 48004 40f ...
Страница 124: ...Operation 7 2 Non operational periods 1PH808 1PH810 main motors 124 Operating Instructions 04 2017 610 48004 40f ...
Страница 144: ...Maintenance 8 2 Corrective maintenance 1PH808 1PH810 main motors 144 Operating Instructions 04 2017 610 48004 40f ...
Страница 147: ...Spare parts 1PH808 1PH810 main motors Operating Instructions 04 2017 610 48004 40f 147 Figure 9 1 Spare parts example ...
Страница 148: ...Spare parts 1PH808 1PH810 main motors 148 Operating Instructions 04 2017 610 48004 40f ...
Страница 185: ......
Страница 186: ......