Commissioning the device
4.4 Configuring the device
Comfort Panels
86
Operating Instructions, 03/2012, A5E03404994-02
4.4.3
Changing password protection
You can protect access to the Control Panel with a password. If you configure password
protection, "SecureMode" is automatically enabled for the HMI device. "SecureMode"
additionally protects the taskbar and the Windows CE Desktop against unauthorized access.
Requirement
The Control Panel is open.
NOTICE
Password not available
If the password is no longer available, the following operator controls are no longer
enabled:
Control Panel
Taskbar
Windows CE Desktop
All data on the HMI device will be deleted when you update the operating system!
Therefore use the password to protect against loss.
Note
The following characters cannot be used in passwords:
Blank
Special characters * ? . % / \ ' "
Procedure
Proceed as follows:
1.
Open the "Password Properties" dialog with the Password icon.
2.
Enter the password under "Password".
3.
Repeat the password under "Confirm password".
4.
Confirm your entry with "OK".
Содержание SIMATIC TP700 Comfort Outdoor
Страница 6: ...Preface Comfort Panels 6 Operating Instructions 03 2012 A5E03404994 02 ...
Страница 12: ...Table of contents Comfort Panels 12 Operating Instructions 03 2012 A5E03404994 02 ...
Страница 24: ...Overview 1 6 Software options Comfort Panels 24 Operating Instructions 03 2012 A5E03404994 02 ...
Страница 28: ...Safety instructions 2 3 Notes about usage Comfort Panels 28 Operating Instructions 03 2012 A5E03404994 02 ...
Страница 136: ...Commissioning the device 4 4 Configuring the device Comfort Panels 136 Operating Instructions 03 2012 A5E03404994 02 ...
Страница 164: ...Operating a project 6 9 Closing the project Comfort Panels 164 Operating Instructions 03 2012 A5E03404994 02 ...
Страница 168: ...Maintenance and care 7 4 Recycling and disposal Comfort Panels 168 Operating Instructions 03 2012 A5E03404994 02 ...