Planning the RF200 system
4.3 Installation guidelines
SIMATIC RF200
78
System Manual, 07/2017, J31069-D0227-U001-A9-7619
Table 4- 33 Reduction of field data due to metal, range as %: Transponder and RF290R
with ANT D6
Transponder
RF290R with ANT D6
Antenna on metal
(metal plate)
Antenna flush-
mounted in metal
(all round 200 mm)
MDS D100
1)
Without metal
100
95
On metal, distance 20 mm
65
60
MDS D124
1)
Without metal
100
95
On metal, distance 25 mm
80
75
MDS D126
1)
Without metal
100
95
On metal, distance 25 mm
65
60
MDS D139
1)
Without metal
100
90
On metal, distance 30 mm
80
70
MDS D160
1)
Without metal
100
90
On metal, distance 25 mm
60
55
MDS D165
Without metal
100
95
On metal, distance 20 mm
50
45
MDS D200
1)
Without metal
100
95
On metal, distance 20 mm
65
60
MDS D261
Without metal
100
95
On metal, distance 20 mm
50
45
MDS D324
1)
Without metal
100
95
On metal, distance 25 mm
75
70
MDS D339
1)
Without metal
100
90
On metal, distance 30 mm
80
70
MDS D400
1)
Without metal
100
95
On metal, distance 20 mm
60
55
MDS D424
1)
Without metal
100
95
On metal, distance 25 mm
75
70
MDS D426
1)
Without metal
100
95
On metal, distance 25 mm
65
60
1)
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
adequate clearance to the metal.
Содержание SIMATIC RF200
Страница 12: ...Table of contents SIMATIC RF200 12 System Manual 07 2017 J31069 D0227 U001 A9 7619 ...
Страница 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2017 J31069 D0227 U001 A9 7619 ...
Страница 25: ...System overview 3 2 Overview of transponders SIMATIC RF200 System Manual 07 2017 J31069 D0227 U001 A9 7619 25 ...
Страница 26: ......
Страница 102: ...Planning the RF200 system 4 4 Further information SIMATIC RF200 102 System Manual 07 2017 J31069 D0227 U001 A9 7619 ...
Страница 160: ......