![Siemens SIMATIC RF200 Скачать руководство пользователя страница 131](http://html.mh-extra.com/html/siemens/simatic-rf200/simatic-rf200_system-manual_382134131.webp)
Readers
5.5 SIMATIC RF250R
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
131
6GT2821-5AC10
6GT2821-5AC40
Antenna
external, ANT 8, ANT 12, ANT 18, ANT 30 can
be connected
Mechanical specifications
Housing
•
Material
•
Plastic PA 6.6
•
Color
•
Anthracite
Recommended distance to metal
0 mm
Supply voltage, current consumption, power loss
Supply voltage
24 VDC
Typical current consumption
50 mA
Permitted ambient conditions
Ambient temperature
•
During operation
•
-20 … +70 °C
•
During transportation and storage
•
-25 … +85 °C
Degree of protection to EN 60529
IP65
Shock-resistant to EN 60721-3-7, Class 7 M3
500 m/s
2
Vibration-resistant to EN 60721-3-7, Class 7 M3 200 m/s
2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (L x W x H)
50 × 50 × 30 mm
Weight
60 g
Type of mounting
2 x M5 screw
1.5 Nm
Cable length, maximum
•
RS-422: max. 1000 m
•
RS-232: max. 30 m
LED display design
3-color LED
5.5.6
Approvals
FCC information
Siemens SIMATIC RF250R (MLFB 6GT2821-5AC10) FCC ID NXW-RF250R
Siemens SIMATIC RF250R (MLFB 6GT2821-5AC40) FCC ID NXW-RF250R
Содержание SIMATIC RF200
Страница 12: ...Table of contents SIMATIC RF200 12 System Manual 07 2017 J31069 D0227 U001 A9 7619 ...
Страница 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2017 J31069 D0227 U001 A9 7619 ...
Страница 25: ...System overview 3 2 Overview of transponders SIMATIC RF200 System Manual 07 2017 J31069 D0227 U001 A9 7619 25 ...
Страница 26: ......
Страница 102: ...Planning the RF200 system 4 4 Further information SIMATIC RF200 102 System Manual 07 2017 J31069 D0227 U001 A9 7619 ...
Страница 160: ......