![Siemens SIMATIC RF200 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/siemens/simatic-rf200/simatic-rf200_system-manual_382134055.webp)
Planning the RF200 system
4.3 Installation guidelines
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
55
4.3.4.1
RF210R
The RF210R can be flush-mounted in metal. Please allow for a possible reduction in the field
data values. To avoid reduction in the case of d), the distance a should be
≥ 10
mm.
The following table shows the different arrangements for the reader with and without a
metallic environment:
Case
Diagram
Description
a)
Reader metal-free
b)
Reader on metal,
distance from metal
≥ 12
mm
c)
Reader in metal,
flush against M18 nut
d)
Reader in metal,
all around