Table 4- 12 Field data SIMATIC RF290R, with ANT D5 (at 4 W)
Length of the transmis-
sion window (L)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D100
320
0 ... 400
500
MDS D124
300
0 ... 200
280
MDS D126
320
0 ... 350
400
MDS D139
320
0 ... 400
500
MDS D160
300
0 ... 130
180
MDS D165
320
0 ... 350
450
MDS D200
320
0 ... 400
500
MDS D261
320
0 ... 300
400
MDS D324
300
0 ... 200
280
MDS D339
320
0 ... 300
380
MDS D400
320
0 ... 400
500
MDS D424
300
0 ... 200
280
MDS D426
320
0 ... 300
350
MDS D460
300
0 ... 120
160
MDS D524
300
0 ... 200
280
MDS D526
320
0 ... 300
350
All dimensions in mm.
Table 4- 13 Field data SIMATIC RF290R, with ANT D6 (at 4 W)
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
X direction Y direction
MDS D100
520
420
0 ... 550
650
MDS D124
500
400
0 ... 220
300
MDS D126
520
420
0 ... 400
500
MDS D139
520
420
0 ... 500
600
MDS D160
500
400
0 ... 130
180
MDS D165
520
420
0 ... 400
500
MDS D200
520
420
0 ... 500
600
MDS D261
520
420
0 ... 350
450
MDS D324
500
400
0 ... 200
280
MDS D339
520
420
0 ... 400
480
MDS D400
520
420
0 ... 500
650
MDS D424
500
400
0 ... 220
300
MDS D426
520
420
0 ... 350
400
MDS D524
500
400
0 ... 220
300
MDS D526
520
420
0 ... 350
400
All dimensions in mm.
Содержание SIMATIC RF200
Страница 12: ...Table of contents SIMATIC RF200 12 System Manual 07 2017 J31069 D0227 U001 A9 7619 ...
Страница 18: ...Safety notes SIMATIC RF200 18 System Manual 07 2017 J31069 D0227 U001 A9 7619 ...
Страница 25: ...System overview 3 2 Overview of transponders SIMATIC RF200 System Manual 07 2017 J31069 D0227 U001 A9 7619 25 ...
Страница 26: ......
Страница 102: ...Planning the RF200 system 4 4 Further information SIMATIC RF200 102 System Manual 07 2017 J31069 D0227 U001 A9 7619 ...
Страница 160: ......