Operating the device
5.5 Monitoring of the device
Operating Instructions, 01/2021, A5E43920357-AA
83
5.5
Monitoring of the device
5.5.1
Monitoring functions
You can monitor the following device functions with the SIMATIC DiagBase or SIMATIC
DiagMonitor software:
Monitoring
Description
Status display and actions
Temperature
monitoring
•
Monitoring of high and low temperature limits and
cable break of the temperature sensors
•
For this, temperature sensors record the temperature
at critical points of the device, e.g. at the processor.
•
The temperature thresholds are defined for the
individual temperature sensors.
•
With SIMATIC IPC DiagBase or SIMATIC IPC
DiagMonitor, actions are triggered when the
temperature thresholds are exceeded.
•
Status display "TEMP (Page 31)"
•
Closed-loop speed control of the
device fans, the power supply fan
and the fan of the optional graphics
card
•
Temperature alarm is output.
Fan monitoring
•
Monitoring of underspeed and failure of a fan as well
as cable break of the tachometer cable
The operation of the fan is monitored at the following
positions:
•
Front panel
•
Processor
•
Optional graphics card
•
Power supply (not redundant)
•
Drive cage type A
•
Status display "FAN (Page 31)"
•
Fan alarm is output.
Watchdog
•
Monitoring of the system status and message as to
whether a station is still operational.
•
If the watchdog is not operated within a configured
monitoring time, a watchdog alarm is output.
•
A change to the monitoring time is effective
immediately.
•
Status display "WATCHDOG
(Page 31)"
Depending on the setting, the following
actions are initiated:
•
Reset on: A hardware reset is carried
out
Monitoring of the
voltages
•
Monitoring of the charge status of the buffer battery
(CMOS)
•
When the first warning threshold is reached, the
backup battery will run for at least 1 more month.
•
If a critical or error status occurs, an
alarm is output.
Drive monitoring
•
Determination of the status of the drives (HDD and
SSD) with SMART functionality (SMART: Self-
Monitoring, Analysis and Reporting Technology) also
in RAID systems (RAID state)
•
The status of an inactive hot swap drive is not
displayed.
•
Status display "HDDx ALARM
(Page 31)"
•
SMART status of the hard drives
•
The following statuses, for example,
are displayed in a RAID system:
"Normal", "OK", "Degraded", error
"Rebuild", rebuilding
Содержание SIMATIC IPC547J
Страница 10: ...Table of contents 10 Operating Instructions 01 2021 A5E43920357 AA ...
Страница 74: ...Commissioning the device 4 3 Switching off the device 74 Operating Instructions 01 2021 A5E43920357 AA ...
Страница 166: ......
Страница 170: ......
Страница 192: ...Markings and symbols C 5 Interfaces 192 Operating Instructions 01 2021 A5E43920357 AA ...