Network integration
6.3 Structure of the data block
SIMATIC Ident CB Gate
Operating Instructions, 08/2022, C79000-G8976-C671-01
33
Table 6- 4
Structure of the "MCSInterface" data block
Variable
Data type
Offset
S7
Offset
TCP
Comment
Interface.
FromMCS
STRUCT
0.0
--
Structure that is received
from the higher-level system.
EnableGate
BOOL
0.0
--
Enable gate.
DisableGate
BOOL
0.1
--
Disable gate.
ResetGate
BOOL
0.2
--
Reset gate.
ResetStatistic
BOOL
0.3
--
Reset statistics.
Reserve04
BOOL
0.4
--
<Reserve>
Reserve05
BOOL
0.5
--
<Reserve>
Reserve06
BOOL
0.6
--
<Reserve>
Reserve07
BOOL
0.7
--
<Reserve>
ConveyorSpeed
REAL
2.0
--
<Is not used>
Interface.
ToMCS
STRUCT
6.0
0.0
Structure that is sent to the
higher-level system
GateEnabled
BOOL
6.0
0.0
Gate is enabled.
InWork
BOOL
6.1
0.1
Read operation active.
FinishedWith
Data
BOOL
6.2
0.2
Read operation with data
ended.
Finished
WithoutData
BOOL
6.3
0.3
Read operation without data
ended because no transponder
was clearly identified.
FinishedObject
Lost
BOOL
6.4
0.4
Read operation was aborted
because the previous object
is still being processed.
Reserve5
BOOL
6.5
0.5
<Reserve>
Reserve6
BOOL
6.6
0.6
<Reserve>
Reserve7
BOOL
6.7
0.7
<Reserve>
Reserve10
BYTE
7.0
1.0
<Reserve>
Reserve
WORD
8.0
2.0
<Reserve>
TelegramID
UNIT
10.0
4.0
ID of sent telegram.
Is incremented when a
telegram is sent.
Range of values 1...65535.
ResultID
UNIT
12.0
6.0
ID of the result.
Is incremented on each new
result.
Range of values 1...65535.
Orientation
INT
14.0
8.0
Alignment of the object
•
0 = Unknown
•
1 = Tag top
•
2 = Tag bottom
Transponder
IID_IN_I_8
1
16.0
10.0
Transponder data of the
detected transponder
Reserved
BYTE
16.0
10.0
ID_Len
BYTE
17.0
11.0
Length of the EPC ID
EPC_ID
ARRAY
[1..62] of
Byte
18.0
12.0
EPC ID
tagPC
WORD
80.0
74.0
--
RSSI
BYTE
82.0
76.0
RSSI value
MaxRSSI
BYTE
83.0
77.0
Highest RSSI value
MinRSSI
BYTE
84.0
78.0
Lowest RSSI value
channel
BYTE
85.0
79.0
Channel
Содержание SIMATIC Ident CB Gate
Страница 20: ...Description SIMATIC Ident CB Gate 20 Operating Instructions 08 2022 C79000 G8976 C671 01 ...
Страница 62: ...Alarm error and system messages SIMATIC Ident CB Gate 62 Operating Instructions 08 2022 C79000 G8976 C671 01 ...
Страница 64: ...Maintenance and service SIMATIC Ident CB Gate 64 Operating Instructions 08 2022 C79000 G8976 C671 01 ...
Страница 70: ...Service Support SIMATIC Ident CB Gate 70 Operating Instructions 08 2022 C79000 G8976 C671 01 ...