  This instruction manual is for the installation of conduit box kits which are used for VF-AS1 

and VF-PS1 inverters. Before installing, please read this manual carefully and be sure to 

understand its contents.

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание TOSVERT VF-AS1 Series

Страница 1: ... Kit Option Installation Manual NOTICE This instruction manual is for the installation of conduit box kits which are used for VF AS1 and VF PS1 inverters Before installing please read this manual carefully and be sure to understand its contents ...

Страница 2: ...itable inverters 2 4 Outline dimension with conduit box kit 3 5 Components 4 6 Installation dimensions 4 7 Installation procedure 6 Installation procedure for group I 6 Installation procedure for group II 6 Installation procedure for group III 8 8 Product support 11 ...

Страница 3: ... Wait at least 15 minutes and make sure that the charge lamp is no longer lit Use a tester to make sure that the voltage to the DC main circuits between PA and PC is 45 V or less Refer to DC voltage test procedure below for details Close all covers before turning on power or starting an inverter Failure to follow these instructions will result in death or serious injury DC voltage test Please use ...

Страница 4: ... 22 2 2 30 22 22 3 0 30 30 30 NEM1107Z 37 37 NEM1117Z 30 45 30 45 NEM1108Z 45 75 37 90 45 75 37 90 55 90 NEM1109Z 55 90 75 110 NEM1110Z 75 110 90 132 NEM1111Z 132 110 160 160 110 200 NEM1112Z 160 220 NEM1113Z NEM1114Z 200 280 200 315 250 315 250 400 355 400 NEM1115Z 400 500 500 NEM1116Z 500 400 630 630 630 Note The different point between NEM1114Z and NEM1113Z is that there is a mounted braking un...

Страница 5: ... 152 NEM1102Z 158 373 164 NEM1103Z 177 416 164 NEM1104Z 212 433 191 NEM1105Z 232 609 191 NEM1106Z 240 495 212 NEM1107Z 240 625 242 NEM1117Z 320 728 242 NEM1108Z 320 793 290 NEM1109Z 325 915 375 NEM1110Z 365 1094 375 NEM1111Z 345 1280 377 NEM1112Z 445 1340 377 NEM1113Z 600 1340 377 NEM1114Z 670 1340 377 NEM1115Z 895 1640 456 NEM1116Z 1125 1640 481 3 ...

Страница 6: ...15 13 8 15 15 15 15 15 M6X16 screws 6 6 10 10 10 10 10 10 Note The hardware clip set includes a hardware clip a M5 nut and a conical washer Installation dimensions For NEM1109Z or those bigger sizes a support frame is installed between the conduit box and the board where the inverter is fixed on The installation dimensions are shown on below table Please refer to figure 2 for NEM1109Z to NEM1115Z ...

Страница 7: ...E6581810 inverter Figure 2 inverter Figure 3 5 ...

Страница 8: ...table 1 when you torque a screw Step1 Do DC voltage test for safety Step2 Remove the power terminal protective cover A Please refer to the instruction manual of inverter for details See figure 4 Step3 Remove the three green ground screws B from the inverter and install them in the three holes C at the base of the conduit box See figure 5 Figure 4 A Figure 5 C B Step4 Attach the conduit box to the ...

Страница 9: ...e 1 when you torque a screw Step1 Do DC voltage test for safety Step2 Remove the front cover of the inverter G See figure 7 Step3 Remove the three green ground screws H from the inverter and install them in the three holes I at the base of the conduit box See figure 8 Figure 8 I H Figure 7 G 7 ...

Страница 10: ... connections to the inverter through the knockouts of the conduit box Step8 Attach the conduit box cover L to the conduit box K with four M4 screws See figure 9 Step9 Replace the inverter cover G removed in step2 L G J K Figure 9 3 Installation procedure for group III Use the torque value in table 1 when you torque a screw Step1 Do DC voltage test for safety Step2 Remove the front cover M from the...

Страница 11: ... the two sides of support frame N and clip the support frame The hardware clip set includes a hardware clip a M5 nut and a captive conical washer See figure 12 Step5 Attach the conduit box P to the support frame with M6 screws See figure 13 N inverter O N P Figure 12 Figure 13 9 ...

Страница 12: ...t damage Step7 Install the EMC plate 2 R as shown in figure 15 This step is only for conduit box kit NEM1109Z R Q Figure 15 Figure 14 Step8 Install the conduit plate S with M4 screws The knockouts provided are for control cables Use either a hole saw or a punch to cut entries for power cables See figure 16 Step9 Make all power and control connections to the inverter Step10 Install the conduit box ...