Preset configuration
The readers and the antennas of the CB Gate are preconfigured in the factory. Depending on
which system variant you are using, the CB Gate has two or four antennas and one or two
read points. All read points/antennas of the reader are configured as follows in the factory:
•
The "Settings > Read point > Assigned antennas" menu
–
Radiated power (ERP): 22 dBm
–
RSSI threshold: 40
–
Input attenuation: 0
–
Sensitivity of the antenna test: 3.7 dBr
•
The "Settings > Read point > Algorithms" menu
–
Smoothing: Observed Count = 3; Lost Count = 100
–
Read/Write Power Ramp: Is enabled (3, 6)
–
Command Retry: Is enabled (10)
–
Inventory Power Ramp: Is disabled
–
RSSI Delta: 0
–
Black List: Size = 0