Method of operation
The CB Gate is built around a conveyor system (e.g. conveyor belt). As soon as an object
passes the light barrier, the read operation starts. Read operations are performed as long as
the light barrier is interrupted. The read result is output via the connected Panel and possibly
to a higher-level system, depending on the settings.
Scope of delivery
The scope of delivery depends on the system variant ordered, but consists mainly of the
following components:
Table 3- 1
System components
Components
Quantity
Article number
Control cabinet components
Controller
SIMATIC S7
CPU 1212C
1
6ES7212-1AE40-0XB0
Reader
SIMATIC RF680R
1
6GT2811-6AA10-0AA0
Switch
SCALANCE XB005
1
6GK5005-0BA00-1AB2
Power supply unit
SITOP PSU6200
1
6EP3334-7SB00-3AX0
External components
Antennas
SIMATIC RF650A
2 or 4
1)
6GT2812-0GB08
Panel
SIMATIC HMI TP900 Comfort
1
6AV2124-0JC01-0AX0
1)
Depending on the system variant
The CB Gate is delivered in a partially pre-mounted state and contains all relevant, passive
components that are required for installation, connection and operation.
Содержание SIMATIC Ident CB Gate
Страница 20: ...Description SIMATIC Ident CB Gate 20 Operating Instructions 08 2022 C79000 G8976 C671 01 ...
Страница 62: ...Alarm error and system messages SIMATIC Ident CB Gate 62 Operating Instructions 08 2022 C79000 G8976 C671 01 ...
Страница 64: ...Maintenance and service SIMATIC Ident CB Gate 64 Operating Instructions 08 2022 C79000 G8976 C671 01 ...
Страница 70: ...Service Support SIMATIC Ident CB Gate 70 Operating Instructions 08 2022 C79000 G8976 C671 01 ...