SIJECT OP15B Screens
SIJECT 16i Operation Manual
3-47
Fig 3-40
Core 1 in/out --- screen 2
On Core 1 screen 1 (see Fig 3-39), press softkey F5
to enter Core 1
screen 2. See Fig 3-40. Core 3 in/out can be set here.
The screen displays the core 3 in/out status, and the related parameters
can be set here, including the position, pressure, flow, time and counter.
The core operation can be controlled by position, by time, or by counter.
Core 3 in
set the pressure and flow for core 3 in. If it is by position, then
position value should be set. If it is by time, then the time should be set as
a parameter and the actual time will be displayed. If it is by counter, then
the counter should be set and the actual counting value will be displayed.
Core 3 out
set the pressure and flow for core 3 out. If it is by position,
then position value should be set. If it is by time, then the time should be
set as a parameter and the actual time will be displayed. If it is by counter,
then the counter should be set and the actual counting value will be
displayed.
Core 3 selection (CorSelect)
select or deselect core 3 in/out.
Core 3 mode (CorMode)
select position mode, time mode or counter
mode.
Core in position (CorInPos)
set the position to do core in. The core in
can be at the start of mold close, during mold close, or at the end of mold
close.
Core out position (CorOutPos)
set the position to do core out. The
core out can be at the start of mold close, during mold close, or at the end
of mold close.
Mold position (MldPos)
display the current position of mold.
Press soft key F3 “Core in” to insert the core into mold, and press F4 “Core
out” to do core out.