SIJECT OP15B Screens
SIJECT 16i Operation Manual
3-36
Fig. 3-33
Service screen 2.4 – Ramp setting
Operating Sequences On service screen 1, press softkey F2
to enter Service screen 2 ---
linear scale setting. Then, press softkey F5
RAMP
to enter ramp setting
screen. See Fig. 3-33 Service Screen 2.4 --- setting ramp data. The ramp
data for every movement can be set accordingly.
Mold Close --- there are four ramps to be set: pressure and flow for each
ramp, and ranged from 0 to 99. The values should be the differences for
pressure and flow between every two PLC cycles when there is action
switch.
Carriage --- it refers to the ramps during carriage advance and carriage
retract: set pressure and flow for each, and ranged from 0 to 99. The
values should be the differences for pressure and flow between every two
PLC cycles when there is action switch.
Inject --- it refers to the ramps when injection starts and injection
completes: set pressure and flow for each, and the range is from 0 to 99.
The values should be the differences for pressure and flow between every
two PLC cycles when there is action switch.
Charge --- it refers to the ramps when charging starts and charging
completes: set pressure and flow for each, and the range is from 0 to 99.
The values should be the differences for pressure and flow between every
two PLC cycles when there is action switch.
Mold Open --- there are four ramps to be set: pressure and flow for each
ramp, and ranged from 0 to 99. The values should be the differences for
pressure and flow between every two PLC cycles when there is action
switch.
Ejector --- it is the ramp before and after the actions of ejector: setting
pressure and flow for each, and the range is from 0 to 99. The values
should be the differences for pressure and flow between every two PLC
cycles when there is action switch.
Decompression --- it refers to the ramps when decompression begins and
decompression completes: set pressure and flow for each, and the range is
from 0 to 99. The values should be the differences for pressure and flow
between every two PLC cycles when there is action switch