SIJECT OP15B Screens
SIJECT 16i Operation Manual
3-45
3.2.5 Charging screen
Fig 3-38
Charging screen
Operating sequences
Press the Charging key to enter the charging screen. See Fig 3-38.
Four charging statuses are provided on the screen, and related parameters
can be set here, including position, pressure and flow. In addition,
backpressure can be selected to set the pressure.
Pre-decompression
implement decompression before charging, and
the position, pressure and flow can be set here.
Charging 1
set the position, pressure and flow for charging 1. If
proportional backpressure valve is used, then the value should be set as
backpressure.
Charging 2
set the position, pressure and flow for charging 2. If
proportional backpressure valve is used, then the value should be set as
backpressure.
Charging 3
set the position, pressure and flow for charging 3. If
proportional backpressure valve is used, then the value should be set as
backpressure.
Charging 4
set the position, pressure and flow for charging 4. If
proportional backpressure valve is used, then the value should be set as
backpressure.
Decompression (Dec)
implement decompression after charging, and
the position, pressure and flow can be set here.
Back pressure selection (BP Select)
you can select the proportional
backpressure valve or deselect it.
Screw position (ScwPos)
display the current position of screw.
Screw rotation speed (ScwRmp)
display the actual screw rotation
speed.
In manual mode, press charging key
to begin charging. Release the
the key , and the charging will stop.