SIJECT OP15B Screens
SIJECT 16i Operation Manual
3-27
Fig 3-26
Service screen 2 – linear scale setting
Linear scale setting
Press soft key F2
to enter the next service screen
see Fig. 3-26
Service screen 2 --- linear scale setting.
Linear Scale mold:
Switch --- Proximity switch signal. When mold close is at position, the box
will backlight, showing the reference point of linear scale.
Reference point --- setting value. Mold lock end should be the reference
of linear scale.
Length --- setting value. The length of linear scale can be set here, ranged
from 1
6553mm.
Actual value --- displayed value. Display the actual value of linear scale.
Current value --- displayed value. It is the difference from actual value to
reference point.
Linear scale injection:
Reference point --- setting value. Reference point of linear scale can be
set here.
Length --- setting value. The length of linear scale can be set here, ranged
from 1
6553mm.
Actual value --- displayed value. Display the actual value of linear scale.
Current value --- displayed value. It is the difference from actual value to
reference point.
Linear scale ejector:
Switch --- Proximity switch signal. When ejector retract is at position, the
box will backlight, showing the reference point of linear scale.