SIJECT OP15B Screens
SIJECT 16i Operation Manual
3-31
Fig 3-29
Service screen 1.3 – Proportional valve adjustment
Operating sequences Press softkey F5
to enter proportional valve adjustment screen. See
Fig.3-29 Service Screen 1.3 --- proportional valve adjustment. Proportional
valve can be adjusted here, and you can test pressure, flow and back-
pressure in force output mode.
Adjust Valve --- select On/Off to start valve adjustment.
Valve Type --- select the type of valve: flow / pressure / back-pressure /
reserved.
Valve Limit --- select min. / max. value.
Pressure Test --- in force output mode, input pressure value, ranged from
0
140bar.
Flow Test --- in force output mode, input flow value, ranged from
0
100
.
BackPressure Test --- in force output mode, input pressure value, ranged
from 0
140bar.
Operating sequences Firstly, start valve adjustment:
Select “ON” in Adjust Valve mode:
1. Use cursor key
or
to enter valve adjustment selection;
2.
Press selection key
, and the cursor moves to left;
3. Use cursor key
or
to select “ON”;
4. Press Enter key to confirm.