Appendix
A.1 Measured variables
SENTRON PAC4200
178
Manual, 09/2008, A5E02316180B-01
Name
Abbrev.
DE + IEC
Abbrev.
EN + NAFTA
Unit
Dis-
play
LIM
SOURCE
Active Energy Import Tariff 1
E
a T1 imp
Wh
T1 imp
Wh
19.0
Active energy imported at tariff 1
Active Energy Import Tariff 2
E
a T2 imp
Wh
T2 imp
Wh
19.0
Active energy imported at tariff 2
Active Energy Export Tariff 1
E
a T1 exp
Wh
T1 exp
Wh
19.1
Active energy exported at tariff 1
Active Energy Export Tariff 2
E
a T2 exp
Wh
T2 exp
Wh
19.1
Active energy exported at tariff 2
Reactive Energy Import Tariff 1
E
r T1 imp
VARh
VARh 20.0
Reactive energy imported at tariff 1
Reactive Energy Import Tariff 2
E
r T2 imp
VARh
VARh 20.0
Reactive energy imported at tariff 2
Reactive Energy Export Tariff 1
E
r T1 exp
VARh
VARh 20.1
Reactive energy exported at tariff 1
Reactive Energy Export Tariff 2
E
r T2 exp
VARh
VARh 20.1
Reactive energy exported at tariff 2
Amplitude Unbalance Voltage
U
nba
Unbal V
ampl
%
–
Unbal V
Unbalance calculated from the voltage amplitudes
Amplitude Unbalance Current
I
nba
Unbal I
ampl
%
–
Unbal I
Unbalance calculated from the current amplitudes
Unbalance Voltage
U
nb
Unbal V
%
23.0 Unbal V
Unbalance calculated from the magnitude of the current amplitudes and three-phase angles
Unbalance Current
I
nb
Unbal I
%
23.0 Unbal I
Unbalance calculated from the magnitude of the voltage amplitudes and three-phase angles
Distortion Current a
I
d L1
I
d a
A
–
I D a
Current of all harmonics in phase conductor a
Maximum distortion current a
I
d L1 max
I
d a max
A
–
Maximum current of all harmonics in phase conductor a
Distortion current b
I
d L2
I
d b
A
–
I D b
Current of all harmonics in phase conductor b
Maximum distortion current b
I
d L2 max
I
d b max
A
–
Maximum current of all harmonics in phase conductor b
Distortion current c
I
d L3
I
d c
A
–
I D c
Current of all harmonics in phase conductor c
Maximum distortion current c
I
d L3 max
I
d c max
A
–
Maximum current of all harmonics in phase conductor c
Universal Counter
–
–
–
21.0
User-configurable counter for counting events or energy
Содержание SENTRON PAC4200
Страница 66: ...Installation 5 4 Deinstalling SENTRON PAC4200 66 Manual 09 2008 A5E02316180B 01 ...
Страница 84: ...Connecting 6 5 Grounding of the Ethernet cable SENTRON PAC4200 84 Manual 09 2008 A5E02316180B 01 ...
Страница 118: ...Operator control 8 3 Special displays SENTRON PAC4200 118 Manual 09 2008 A5E02316180B 01 ...
Страница 146: ...Parameterizing 9 2 Parameterizing the operator interface SENTRON PAC4200 146 Manual 09 2008 A5E02316180B 01 ...
Страница 152: ...Service and maintenance 10 6 Disposal SENTRON PAC4200 152 Manual 09 2008 A5E02316180B 01 ...
Страница 168: ...Dimension drawings SENTRON PAC4200 168 Manual 09 2008 A5E02316180B 01 ...
Страница 252: ...Index SENTRON PAC4200 252 Manual 09 2008 A5E02316180B 01 ...