9 4
Ordering Information
Encased Systems Circuit Breakers and Electronic Trip Units
Type SB Encased Systems Breaker Frames Alternate Interrupting Rating (To 85 A.l.R. (kA))
Breaker Type
Fixed Mounted
Catalog Number
Drawout Breaker with Moveable Mechanism
Stationary Drawout Mechanism
Ampere Rating
Frame Size
Vertical Bus Catalog
Number
Horizontal Bus Catalog
Number
Vertical Bus Catalog
Number
Horizontal Bus Catalog
Number
400
800
1200
1600
2000
800
800
1200
2000
2000
SBA0804F
SBA0808F
SBA1212F
SBA2016F
SBA2020F
SBA0804DV
SBA0808DV
SBA1212DV
SBA2016DV
SBA2020DV
SBA0804DH
SBA0808DH
SBA1212DH
SBA2016DH
SBA2020DH
SBA08DFV
SBA08DFV
SBA12DFV
SBA20DFV
SBA20DFV
SBA08DFH
SBA08DFH
SBA12DFH
SBA20DFH
SBA20DFH
Type SB Encased Systems Breaker Frames Standard Interrupting Rating (To 100 A.l.R. (kA))
Breaker Type
Fixed Mounted
Catalog Number
Drawout Breaker with Moveable Mechanism
Stationary Drawout Mechanism
Ampere Rating
Frame Size
Vertical Bus Catalog
Number
Horizontal Bus Catalog
Number
Vertical Bus Catalog
Number
Horizontal Bus Catalog
Number
400
800
1200
1600
2000
800
800
1200
2000
2000
SBS0804F
SBS0808F
SBS1212F
SBS2016F
SBS2020F
SBS0804DV
SBS0808DV
SBS1212DV
SBS2016DV
SBS2020DV
SBS0804DH
SBS0808DH
SBS1212DH
SBS2016DH
SBS2020DH
SBS08DFV
SBS08DFV
SBS12DFV
SBS20DFV
SBS20DFV
SBS08DFH
SBS08DFH
SBS12DFH
SBS20DFH
SBS20DFH
Type SB Encased Systems Breaker Frames High Interrupting Rating (To 200 A.l.R. (kA))
Breaker Type
Fixed Mounted
Catalog Number
Drawout Breaker with Moveable Mechanism
Stationary Drawout Mechanism
Ampere Rating
Frame Size
Vertical Bus Catalog
Number
Horizontal Bus Catalog
Number
Vertical Bus Catalog
Number
Horizontal Bus Catalog
Number
400
800
1200
1600
2000
800
800
1200
2000
2000
SBH0804F
SBH0808F
SBH1212F
SBH2016F
SBH2020F
SBH0804DV
SBH0808DV
SBH1212DV
SBH2016DV
SBH2020DV
SBH0804DH
SBH0808DH
SBH1212DH
SBH2016DH
SBH2020DH
SBH08DFV
SBH08DFV
SBH12DFV
SBH20DFV
SBH20DFV
SBH08DFH
SBH08DFH
SBH12DFH
SBH20DFH
SBH20DFH
Electronic Trip Unit, 800A Frame
Catalog Number
Frame Ampere Rating
Continuous Current
Setting
Long Time Delay
Instantaneous Pickup
Short Time
Pickup/Delay
Ground Fault
Pickup/Delay
SB04TLI
SB04TLS
SB04TLSI
400
400
400
x
x
x
x
x
x
x
x
x
x
SB04TLIG
SB04TLSG
SB04TLSIG
SB04TMLI
400
400
400
400
x
x
x
x
x
x
x
x
x
x
x
x
x
x
SB08TLI
SB08TLS
SB08TLSI
800
800
800
x
x
x
x
x
x
x
x
x
x
SB08TLIG
SB08TLSG
SB08TLSIG
SB08TMLI
800
800
800
800
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Electronic Trip Unit 1200A Frame
Catalog Number
Frame Ampere Rating
Continuous Current
Setting
Long Time Delay
Instantaneous Pickup
Short Time
Pickup/Delay
Ground Fault
Pickup/Delay
SB12TLI
SB12TLS
SB12TLSI
1200
1200
1200
x
x
x
x
x
x
x
x
x
x
SB12TLIG
SB12TLSG
SB12TLSIG
SB12TMLI
1200
1200
1200
1200
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Содержание SBA 1200
Страница 68: ...66 External Accessories Ground Fault Sensing and Relaying Courtesy of NationalSwitchgear com ...
Страница 88: ...86 Outline Dimension Drawing 2000A Stationary Drawout Element Courtesy of NationalSwitchgear com ...
Страница 89: ...87 Outline Dimension Drawing 2000A Stationary Drawout Element Courtesy of NationalSwitchgear com ...
Страница 90: ...88 Outline Dimension Drawing 2000A Moveable Drawout Element Courtesy of NationalSwitchgear com ...
Страница 91: ...89 Outline Dimension Drawing 2000A Moveable Drawout Element Courtesy of NationalSwitchgear com ...
Страница 92: ...90 Outline Dimension Drawing 800A Fixed Mounted 1200A Fixed Mounted Courtesy of NationalSwitchgear com ...
Страница 93: ...91 Outline Dimension Drawing 800A Fixed Mounted 1200A Fixed Mounted Courtesy of NationalSwitchgear com ...
Страница 94: ...92 Outline Dimension Drawing 2000A Fixed Mounted Courtesy of NationalSwitchgear com ...
Страница 95: ...93 Outline Dimension Drawing 2000A Fixed Mounted Courtesy of NationalSwitchgear com ...
Страница 100: ...98 Courtesy of NationalSwitchgear com ...
Страница 101: ...Electrical Diagrams 99 Courtesy of NationalSwitchgear com ...
Страница 102: ...100 Electrical Diagrams Courtesy of NationalSwitchgear com ...