18/130
Siemens Building Technologies
Basic Documentation RVD230
CE1P2383en
HVAC Products
3 Fundamentals
27.05.2004
Type ref. Diagram
Legend
23
83
S
0
1
H5
B3
Q3
B32
B72
Y5
B9
B3 D.h.w. flow sensor
B32 Return sensor d.h.w.
B72 Primary return sensor
B9 Outside sensor (optional, display only)
H5 Flow switch (optional)
Q3 Circulating pump (optional)
Y5 2-port valve primary return
Y5
B9
B3
B32
Q3
K6
23
83
S
0
2
B31
B72
a)
b)
B3 D.h.w. flow sensor
B31 Storage tank sensor 1
B32 Storage tank sensor 2
B72 Primary return sensor
B9 Outside sensor (optional, display only)
K6 Circulating pump (optional)
Q3 Storage tank charging pump
Y5 2-port valve primary return
B31
K6
B72
B3
Q3
B9
23
83
S
03
Y5
B32
B3 D.h.w. flow sensor
B31 Storage tank sensor 1
B32 Storage tank sensor 2
B72 Primary return sensor
B9 Outside sensor (optional, display only)
K6 Circulating pump (optional)
Q3 D.h.w. intermediate circuit pump
Y5 2-port valve d.h.w. primary return
Y5
B9
B12
B32
Q4
K6
23
83
S
0
4
B31
B72
a)
b)
B3
Q3
B12 D.h.w. flow sensor
B3 D.h.w. flow sensor
B31 Storage tank sensor 1
B32 Storage tank sensor 2
B72 Primary return sensor
B9 Outside sensor (optional, display only)
K6 Circulating pump (optional)
Q3 D.h.w. intermediate circuit pump
Q4 Storage tank charging pump
Y5 2-port valve d.h.w. primary return
Y1
B7
B71
B1
Q1
B9
A6
23
83
S
05
A6 Room unit
B1 Flow sensor heating circuit
B7 Primary return sensor*
B71 Secondary
return
sensor
B9 Outside sensor
Q1 Heating circuit pump
Y1 2-port valve primary return
Y1
B7
B71
B1
Q1
B9
A6
B31
K6
B72
23
83
S
06
Y5
B32
A6 Room unit
B1 Flow sensor heating circuit
B31 Storage tank sensor 1
B32 Storage tank sensor 2
B7 Primary return sensor heating circuit*
B71 Secondary return sensor heating circuit
B72 Primary return sensor d.h.w.
B9 Outside sensor
K6 Circulating pump (optional)
Q1 Heating circuit pump
Y1 2-port valve heating circuit primary return
Y5 2-port valve d.h.w. primary return
B1
Y1
Y5
B7
Q1
A6
B9
23
83
S
0
7
B32
B3
H5
B72
Q3
B71
A6 Room unit
B1 Flow sensor heating circuit
B3 D.h.w. flow sensor
B32 Return sensor d.h.w. circuit
B7 Primary return sensor heating circuit*
B71 Secondary return sensor heating circuit
B72 Primary return sensor d.h.w. circuit
B9 Outside sensor
H5 Flow switch (optional)
Q1 Heating circuit pump
Q3 Circulating pump (optional)
Y1 2-port valve heating circuit primary return
Y5 2-port valve d.h.w. primary return
a) Circulating pump feeding water into the heat exchanger’s return
b) Circulating pump feeding water into the storage tank
* Suppression of hydraulic creep