Error messages
9.3 Error messages of the RF182C
RF182C communication module
Operating Instructions, 10/2010
73
Error code
ASCII hex
Flashing of
ERR LED
1)
Description
0005
5x
Unknown command
The client is sending an uninterpretable command to the communication module.
•
Check the XML command
•
The MDS reported an address error
0006
6x
Field interference on write/read device
The write/read device is receiving interference from its environment.
•
The distance between two write/read devices is too small and does not correspond
to the configuration guidelines
•
The connecting cable to the write/read device is defective or too long or does not
comply with the specification
•
MOBY U: MDS has left the field during communication.
•
MOBY U: Communication between write/read device and MDS was terminated by
interference (e.g. person/foreign body moving between write/read device and MDS).
0007
7x
Too many transmit errors
The MDS was not able to correctly receive the command or the write data from the
communication module even after several attempts.
•
The MDS is positioned exactly on the boundary of the transmission window.
•
Data transmission to the MDS is being affected by external interference.
0008
8x
CRC sending error
•
The receiver monitor has detected at least one fault during transmission.
– Cause same as error 0006
•
MDS signaling CRC error frequently.
– The MDS is positioned exactly on the boundary of the write/read device.
– The hardware of the MDS and/or write/read device is defective.
0009
9x
Only during initialization: CRC error during acknowledgment receipt from MDS
•
Cause same as error 0006
000A
10x
Only during initialization: MDS is unable to perform the initialization command.
•
MDS is defective.
000B
11x
MOBY U: Memory of MDS cannot be read correctly.
000C
12x
Memory of the MDS cannot be write-accessed.
•
Memory of the MDS is defective.
•
EEPROM MDS was written too frequently and has reached the end of its service life
000D
13x
Address error
The address area of the MDS was exceeded.
•
Check the XML command
•
The MDS is not the right type.
•
RF300: Attempted write access to write-protected areas (OTP area)
Содержание RF182C
Страница 12: ...Description RF182C communication module 12 Operating Instructions 10 2010 ...
Страница 20: ...Mounting 3 5 Disassembling the RF182C RF182C communication module 20 Operating Instructions 10 2010 ...
Страница 66: ...Maintenance and Service 7 3 Reader update RF182C communication module 66 Operating Instructions 10 2010 ...
Страница 70: ...Diagnostics 8 1 Diagnostics using LEDs RF182C communication module 70 Operating Instructions 10 2010 ...
Страница 122: ...Command and acknowledgement telegrams RF182C communication module 122 Operating Instructions 10 2010 ...
Страница 128: ...Service support RF182C communication module 128 Operating Instructions 10 2010 ...