Connecting
4.3 Loop-through of Ethernet and supply voltage
RF182C communication module
30
Operating Instructions, 10/2010
4.3
Loop-through of Ethernet and supply voltage
Features
The connection block features one connector for the incoming supply and one socket for
loop-through connection of the supply voltage. The connector and the socket for the supply
are linked with one another internally.
Two sockets are available for the infeed and loop-through of Ethernet. The sockets are not
connected to each other in the connection block. The switch in the base unit creates the
logical connection.
Note
If you disassemble the connection block during operation, only the power supply will be
looped through. Data communication to subsequent devices will be interrupted from this
module onwards.
5)&,2
'HYLFH
GLVFRQQHFWHG
IURP(WKHUQHW
6XSSO\YROWDJHLVORRSHG
WKURXJK
5HPRYH
FRQQHFWLRQEORFN
IURP,2PRGXOH
(WKHUQHWLVLQWHUUXSWHG
5)&
,2'HYLFH
5)&
,2'HYLFH
5)
&
5)
&
5)
&
Figure 4-6
Loop-through of Ethernet and supply voltage
CAUTION
The IP65, IP66 or IP67 degree of protection is no longer guaranteed when the connection
block is dismounted.
Содержание RF182C
Страница 12: ...Description RF182C communication module 12 Operating Instructions 10 2010 ...
Страница 20: ...Mounting 3 5 Disassembling the RF182C RF182C communication module 20 Operating Instructions 10 2010 ...
Страница 66: ...Maintenance and Service 7 3 Reader update RF182C communication module 66 Operating Instructions 10 2010 ...
Страница 70: ...Diagnostics 8 1 Diagnostics using LEDs RF182C communication module 70 Operating Instructions 10 2010 ...
Страница 122: ...Command and acknowledgement telegrams RF182C communication module 122 Operating Instructions 10 2010 ...
Страница 128: ...Service support RF182C communication module 128 Operating Instructions 10 2010 ...