Connecting cable to the reader/SLG
13.2 Self-assembled cable
RF182C communication module
Operating Instructions, 10/2010
107
13.2
Self-assembled cable
A reader/SLG connector plug with screw terminals is provided for users who want to
individually pre-assemble their own cables (refer to the relevant system manual). Cables and
reader/SLG connector plugs can be ordered from the Catalog
FS 10 Sensors for Production
Automation.
Cable structure
You will need cables of the following specifications for self-assembled cables:
7 x 0.25 mm
2
LiYC11Y 7 x 0.25
Connectors
M12 connectors can be obtained from the relevant specialist dealers (e.g. Binder).
Pin assignment
The pin assignment is listed in the following table.
Table 13- 4 Pin assignment
M12 connector (male)
Pin
Signal
Core color
1
1L+ (+ 24 V)
2
−RxD
3
0 V
4
RxD
5
TxD
6
−TxD
7
Free
8
Functional
ground
(PE)/shield
Note data sheet
provided by cable
manufacturer
Содержание RF182C
Страница 12: ...Description RF182C communication module 12 Operating Instructions 10 2010 ...
Страница 20: ...Mounting 3 5 Disassembling the RF182C RF182C communication module 20 Operating Instructions 10 2010 ...
Страница 66: ...Maintenance and Service 7 3 Reader update RF182C communication module 66 Operating Instructions 10 2010 ...
Страница 70: ...Diagnostics 8 1 Diagnostics using LEDs RF182C communication module 70 Operating Instructions 10 2010 ...
Страница 122: ...Command and acknowledgement telegrams RF182C communication module 122 Operating Instructions 10 2010 ...
Страница 128: ...Service support RF182C communication module 128 Operating Instructions 10 2010 ...