Connecting
4.4 Wiring an RF182C to a controller with Ethernet connection
RF182C communication module
32
Operating Instructions, 10/2010
4.4
Wiring an RF182C to a controller with Ethernet connection
A connection from Ethernet to an M12 connection can be easily implemented.
Self-assembly of an Ethernet M12 cable
● You will need a pre-assembled PROFINET/Ethernet cable with M12 connectors at both
ends twice the required length. You will also need two Ethernet connectors for self-
assembly. Cut the M12 cable in the center and connect one Ethernet connector to each
free cable end. This will result in two Ethernet M12 cables.
● You will need the following individual parts: Ethernet plug-in connector, M12 plug-in
connector, and PROFINET/Ethernet standard cable (unassembled). The parts can be
found in the ordering data. You can make up a cable to your own length requirements
using these parts.
Using a cabinet bushing Ethernet M12
This connection variant must always be used when the controller electronics is installed in a
cabinet. The following figure shows the connection layout.
3&
6WDQGDUG5-
(WKHUQHWFDEOH
6WDQGDUG0
(WKHUQHWFDEOH
5-0FDELQHW
EXVKLQJ
5)&
PROFINET IO
Master module
SIMATIC S7
352),1(7,2
Figure 4-7
Cabinet bushing
Содержание RF182C
Страница 12: ...Description RF182C communication module 12 Operating Instructions 10 2010 ...
Страница 20: ...Mounting 3 5 Disassembling the RF182C RF182C communication module 20 Operating Instructions 10 2010 ...
Страница 66: ...Maintenance and Service 7 3 Reader update RF182C communication module 66 Operating Instructions 10 2010 ...
Страница 70: ...Diagnostics 8 1 Diagnostics using LEDs RF182C communication module 70 Operating Instructions 10 2010 ...
Страница 122: ...Command and acknowledgement telegrams RF182C communication module 122 Operating Instructions 10 2010 ...
Страница 128: ...Service support RF182C communication module 128 Operating Instructions 10 2010 ...