7ML19985CN01
Milltronics SF 500 – INSTRUCTION MANUAL
Page 3
mm
mmm
Specificat
io
ns
Specifications
Power
• 100/115/200/230 V ac ±15%, 50/60 Hz, 31 VA
• fuse, FU1 2AG, Slo Blo, 2 A, 250 V or equivalent
Application
• compatible with Siemens Milltronics solids flowmeters or equivalent 1 or 2 load cell
flowmeters
• compatible with LVDT equipped solids flowmeters, with use of optional interface board
Accuracy
• 0.1% of full scale
Resolution
• 0.02% of full scale
Environmental
• location:
indoor / outdoor
• altitude:
2000 m max
• ambient temperature:
-20 to 50°C (-5 to 122°F)
• relative humidity:
suitable for outdoor (Type 4X / NEMA 4X /IP65 enclosure)
• Installation category:
II
• pollution degree:
4
Enclosure
• Type 4X / NEMA 4X / IP65
• 285 mm W x 209 mm H x 92 mm D (11.2” W x 8.2” H x 3.6” D)
• polycarbonate
Programming
• via local keypad and/or Dolphin Plus interface
Display
• illuminated 5 x 7 dot matrix liquid crystal display with 2 lines of 40 characters each
Memory
• program stored in non-volatile FLASH ROM, upgradable via Dolphin Plus interface
• parameters stored in battery backed RAM. The battery is 3V NEDA 5003LC or
equivalent, nominal 5 year life