7ML19985CN01
Milltronics SF 500 – INSTRUCTION MANUAL
Page 9
mmm
mm
Inst
allat
ion
Interconnection
System Diagram
Note:
•
Run wiring via a common conduit
•
Do not run wiring in the same conduit as the high voltage contact or power wiring
•
Ground shield at one point only. Insulate at junctions to prevent inadvertent
grounding.
•
Typical system capability. Not all components or their maximum quantity may be
required
.
fieldbus communication
RS-485
RS-232
RS-232 / RJ - 11
2
1
1
5
5
2
2
Milltronics
SF 500
optional SmartLinx®
optional analog I/O
Solids
flowmeter, See
Specifications,
mA output to
customer device
mA input from
customer device
relay output, to
customer device
auxiliary inputs
customer remote
totalizer
optional fieldbus
connection
mA output to
customer device
communication
ports can be
configured for
Siemens
Milltronics
Dolphin, print
data, or Modbus
ASCII or RTU
protocol